TemperZone SAT-1 User Operating Instructions Manual Download Page 7

Page 7 

Example:

 

Two sessions of on and off timer per day being set as follow:  

P1 on timer  0800 
P1 off timer   1200 
P2 on timer  1300 
P2 off timer  1700 

If current time is 0730 hrs, it will remain as last state. At 0800 hrs, it will turn on 
the unit using P1 on timer. At 1200 hrs, it will turn off the unit using P1 off timer. 
At 1300 hrs, it will turn on the unit using P2 on timer. At 1700 hrs, it will turn off 
the unit using P2 off timer. 
Pressing on/off  button  to  on/off  the  unit  will  bypass  the  control  of  current event. 
The second event will take over upon expiry of current event.  
Example: If user turns off the unit at 1000 hrs, it will remain off until 1300 hrs, at 
which time control is taken over by timer P2. 

Sleep Activation 

Press 

SLEEP

 button  to  activate  the  sleep  option.  This  option  saves  energy  by 

altering the set temperature over a two hours period. 
Example uses: 
In  Summer,  before  going  to  bed  at  night  with  the  cool  mode  set,  pressing  the  

SLEEP

 button gradually raises the set temperature by 2 degrees to compensate 

for a person’s lower metabolism when sleeping. 

In  Winter,  with  the  heat  mode  set,  pressing  the   

SLEEP

 button  gradually  lower 

the set temperature by 3 degrees to compensate for heavier winter bedding. 
The sleep option is only available for Cool, Heat and Auto modes.

 

Zone Control (option) 

If  your  air  conditioning  installation  has  zones  installed  (i.e. dampers), select  the 
zones  to  be  turned  on  using  the  appropriate  Zone  button.  Zone  1  is  always 
assigned  as  master  zone.  Each  zone  can  be  individually  turned  on  or  off. 
However,  zone  1  can  only  be  turned  off  provided  there  are  two  other  zones 
turned on.  

Key Lock 

This feature protects the control being tampered with by children or unauthorized 
persons. 

To  activate,  hold  down   

TIME

 and 

M O D E

 buttons  for  3  seconds,  key  lock 

symbol

 will light up.  

When the key lock is active, 

a) 

 button can be used to on or off the system. 

b) 

 or 

  button can be used to program the Bypass timer (refer below). 

c) 

CANCEL

 can be used to cancel the Bypass timer. 

d)  Other buttons are ignored. 

Summary of Contents for SAT-1

Page 1: ...SAT SAT SAT SAT 1 Thermostat 1 Thermostat 1 Thermostat 1 Thermostat USER S OPERATING INSTRUCTIONS AUTO HEATER SUNMON TUE WED THU FRI SAT OFF ON ERR UNIT HEAT COOL FAN DRY SLEEP AUTO SWING ZONE...

Page 2: ...CONTENTS Page Introduction 3 Features Summary 3 Display 4 Operation 5 Remote Control option 9 Error Code Display 10 Troubleshooting 11 Contact for Service back page...

Page 3: ...range from 16 C to 30 C Room temperature display Real time clock 7 days programmable Start Stop timer that programs the unit to two start stop sessions per day Bypass function enables user to bypass t...

Page 4: ...on Swing button Or used in weekly on off timer programming to select day of week To select day of week Sunday to Saturday Day button Room temperature setting button Press again to stop operation Press...

Page 5: ...the air conditioner cools the room until it reaches the set temperature Dry If the atmosphere in the room is very humid or damp use this mode to both reduce the humidity and cool until the room is nea...

Page 6: ...to select session 1 P1 or session 2 P2 The selected session is indicated on the temperature display area as P1 or P2 c Press DAY button to change the set day of the on or off timer d If the selected t...

Page 7: ...ith the cool mode set pressing the SLEEP button gradually raises the set temperature by 2 degrees to compensate for a person s lower metabolism when sleeping In Winter with the heat mode set pressing...

Page 8: ...is On or Off timer available the unit will continue to operate if the time span of the On or Off timer allows it to be on At an undefined region or off time span the unit will switch off To terminate...

Page 9: ...Fan Heat Auto Adjust Set Temperature Press down or up button to decrease or increase the desired room temperature Note A temperature can not be set in Fan mode Clock Press down or up button for 2 sec...

Page 10: ...board AD3 Room sensor 2 failure 2 Main board AD4 Room sensor 3 failure 3 Main board AD5 Room sensor 4 failure 4 Main board AD6 1 indoor coil sensor failure 5 Main board AD1 1 outdoor coil sensor fail...

Page 11: ...set temperature may have been set too high or too low If the set temperature appears okay call for service Timer is Not Correctly Triggered Check the clock is set to the right time day light saving an...

Page 12: ...ries in the remote control aren t flat 2 The infra red remote control must be pointed directly at the SAT 1 wall thermostat plaque in order for its signal to be received 3 If there is no light or beep...

Page 13: ...AND Temperzone Ltd Phone 0 9 279 5250 Fax 0 9 275 5637 SYDNEY Temperzone Australia Pty Ltd Phone 02 8822 5700 Fax 02 8822 5711 SINGAPORE Phone SNG 6733 4292 Fax SNG 6235 7180 Your local service agent...

Reviews: