background image

 

17

 

 Troubleshooting 

Problem 

Solution 

Power on LED is not lit 

 

Power LED does not turn ON while running on 
batteries. 

 

Is the barrel connector end of the AC adapter plugged 
into the power jack on the FA-700, with the other end of 
the adapter is plugged into a ‘live” AC power source.  

 

Is the AC power wall outlet active? 

CANNOT enter phone 
number 

 

You cannot enter the call-to phone number if the FA-
700 is being powered only by batteries. 

 

Is the FA-700’s AC power adapter plugged into AC 
power?  

 

Follow the “Entering Phone Number” procedure. 

FA-700 DOES NOT call out 
during a test  

 

Does the FA-700 have power? 

 

Is the phone service working properly 

(dial tone)

 

Re-check that the RJ-11 phone cord is fully plugged 
into the phone jack of the FA-700, and into the wall 
jack. 

 

Re-enter the phone number, verify area code and if the 
number “1” is required for long distance calling. 

 

If you are using a phone calling card, check to see that 
the calling sequence includes pauses as may be 
necessary to complete the call. 

FA-700 does not answer 
when I call 

 

The FA-700 will not answer if there is no active alarm 
event in progress. 

 

Is there an answering machine or voice mail in line with 
the FA-700?

 (see procedure for “In phone line 

answering machine/voice mail”) 

 

 

Verify that phone service is active at FA-700 location. 

I cannot cancel the alarm call 
out; the FA-700 continues 
calling out 

 

Do you hear an alarm message that the alarm call out 
has been canceled? 

 

Are you pressing the correct cancel alarm keys during 
the alarm event:  number “1” key and then the pound 
“#” key within one minute? 

Receiving a false alarm 

 

The FA-700’s temperature sensor is accurate to within 
3

°F of the actual temperature. If your FA-700 is too close 

to a window during the winter months 

(below 45°C)

 or 

positioned in direct sun light 

(above 85°C)

 this could cause 

the FA-700 to false alarm.

 

 

Check the FA-700 to see if the batteries installed, No 
batteries installed could cause the FA-700 to issue a 
false alarm. 

 

 

18

 

Technical information 

Technical specification 

Specification 

Description 

Power requirements 

Two power sources: 

 

110VAC power adapter voltage stepped down to 
6VDC, 200mA. 

 

2 AA batteries for backup power 

(

alkaline or lithium 

batteries,

 not provided)

 CHANGE BATTERIES after a 

prolonged AC power failure or yearly. 

Temperature monitoring 

(DIP switch selectable)

 

Temperature drops below 45ºF 

(7ºC)

 or temperature rises 

above 85ºF 

(34ºC)

  

Humidity 

95% 

Dimensions 

5.8in L, 3.5in W, 1.5in H 

(147.3mm, 88.9mm, 38.1mm) 

approximately 

Ring Equivalence 
Number (REN) 

0.1B 

FCC statement 

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the 
ACTA 

(

American Council for Terminal Attachments)

. On the bottom of your FA-700 is a 

label that contains, among other information the FCC registration number for this product. If 
requested, this number must be provided to the telephone company. 

Plug and jack use 

A plug and jack used to connect this equipment to the premises wiring and telephone network 
must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A 
compliant telephone cord and modular plug is provided with this product. It is designed to be 
connected to a compatible modular jack that is also compliant. See installation instructions for 
details. 

Ring equivalence number (REN) 

The REN is used to determine the number of devices that may be connected to a telephone line. 
Excessive REN’s on a telephone line may result in the devices not ringing in response to an 
incoming call. In most, but not all areas, the sum of RENs should not exceed five (5.0). To be 
certain of the number of devices that may be connected to a line, as determined by the total RENs, 
contact your local telephone company. The REN for this product is shown above and is also 
identified as part of the FCC product identifier

 

shown on the label on the back of your FA-700.  

Telephone network interferences  

If this FA-700 causes harm to the telephone network, the telephone company will notify you 
in advance that temporary discontinuance of service may be required. But if advance notice 
isn’t practical, the telephone company will notify the customer as soon as possible. Also, you 
will be advised of your right to file a complaint with the FCC if you believe it is necessary. 
 
The telephone company may make changes in its facilities, equipment, operations or 
procedures that could affect the operation of the equipment. If this happens, the telephone 
company will provide advance notice in order for you to make necessary modifications to 

Summary of Contents for FreezeAlarm Dialer CNPREC001

Page 1: ...nging the call to phone number 13 Installation considerations 13 FA 700 assembled 13 Phone test 14 Testing your FA 700 14 Testing for a specific alarm condition 14 Ring count timer 14 Calling the FA 7...

Page 2: ...Warnings Cautions and warnings appear here and may appear throughout this manual where appropriate Failure to read and understand the information identified by these symbols could result in poor equi...

Page 3: ...FA 700 will start calling the programmed phone number over a standard phone line and describe in English the current alarm s The FA 700 will continue calling until the alarm call out is canceled LEDs...

Page 4: ...switch orientation Figure 2 DIP Switches Note Use a ballpoint pen or similar small object to set the DIP switches 8 Table 3 DIP switch settings and functions Switch Function switch in UP position is t...

Page 5: ...extended AC power failure it is recommended that you replace the batteries Also a false low battery alarm can occur if the AA batteries have not been installed and AC power is connected to the FA 700...

Page 6: ...owed by the pound key Make sure to include all necessary key presses as you enter the number Also while the card or pager system is talking number of seconds you will need to enter pauses for that tim...

Page 7: ...number it is crucial that you test your FA 700 to verify that it can reach the programmed phone number Note The CANCEL key does not function when the FA 700 is in test mode Testing your FA 700 To test...

Page 8: ...lls within 3 minutes to get the FA 700 to eventually answer How to cancel an alarm call out You can cancel an alarm call out in two ways Remotely press the number 1 key and then the pound key at any t...

Page 9: ...up power alkaline or lithium batteries not provided CHANGE BATTERIES after a prolonged AC power failure or yearly Temperature monitoring DIP switch selectable Temperature drops below 45 F 7 C or tempe...

Page 10: ...g One Year Limited Warranty Protected Home warrants its product to be free from defects in material and workmanship under normal use for one year and is not responsible for consequential damages or in...

Page 11: ...the package containing the product How to request an RGA number To request a RGA call Protected Home at 952 448 2217 and ask for Customer Service Failure to have a RGA may result in lost product or si...

Reviews: