Avoid pointing the detector towards objects that may move in the wind, such as curtains, 

tall plants etc. 

 

 

 

 

CONNECTION: 

 

                   

Warning. Danger of death through electric shock! 

 

Must be installed by professional electrician. 

 

Disconnect power source. 

 

Cover or shied any adjacent live components. 

 

Ensure device cannot be switched on. 

 

Check power supply is disconnected. 

 

 

Unload the front cover directly by screw-driver. (figure1).Find the wire hole with gasket in 

the bottom and pass the power wire through hole. 

 

Fix the bottom on the selected position with the inflated screw (refer to figure 2). 

 

Connect  the  power  wire  into  connection-wire  column  according  to  the  connection-wire 

diagram. 

 

Install back the front cover, tighten the screw and switch on the power. Then you can test 

it. 

 

 

 

                                                          Figure1                                                                    Figure2 

 

 

CONNECTION-WIRE DIAGRAM:

 

(See the right figure) 

 

 

 

 

 

 

 

SENSOR INFORMATION: 

 

 

 

 

 

 

 

 

 

 

 

TEST : 

  Turn  the  SENS  knob  clockwise  on  the  maximum  (+).Turn 

the TIME knob  anti-clockwise on the minimum (-).Turn the 

LUX knob clockwise on the maximum (sun).     

  Switch on the power; the sensor and its connected lamp will 

have no signal at the beginning. After Warm-up 30sec, the 

sensor can  start  work  .If  the sensor  receives  the  induction 

signal,  the  lamp  will  turn  on.  While  there  is  no  another 

induction signal any more, the load should stop working within 10sec

±

3sec and the lamp 

would turn off.   

 

Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 

3LUX, the sensor would not work and the lamp stop working too. If the ambient light is 

less than 3LUX (darkness), the sensor would work. Under no induction signal condition, 

the sensor should stop working within 10sec

±

3sec. 

 

Note: when testing in daylight, please turn LUX knob to          (SUN) position, otherwise 

the  sensor  lamp  could  not  work!  If  the  lamp  is  more  than  60W,  the  distance  between 

lamp and sensor should be 60cm at least. 

 

Height of installation: 1.8-2.5m 

Detection Distance: Max.12m 

 

Summary of Contents for KOBAN 0775871

Page 1: ...UNCTION Can identify day and night The consumer can adjust working state in different ambient light It can work in the daytime and at night when it is adjusted on the sun position max It can work in t...

Page 2: ...TEST Turn the SENS knob clockwise on the maximum Turn the TIME knob anti clockwise on the minimum Turn the LUX knob clockwise on the maximum sun Switch on the power the sensor and its connected lamp w...

Page 3: ...receive the signals b Please check if the ambient temperature is too high c Please check if the induction signal source is in the detection field d Please check if the installation height corresponds...

Page 4: ...de trabajo 20 40 Ajuste de tiempo Min 10sec 3sec Humedad de trabajo 93 RH Max 7min 2min Potencia consumida approx 0 5W Cargas soportadas Max 1200W Altura de instalaci n 1 8 2 5m 300W Detecci n de mov...

Page 5: ...ctada Quite la carcasa frontal directamente con un destornillador Figura 1 Afloje los tornillos en el terminal de conexi n y luego conecte el cable de alimentaci n al terminal de conexi n del sensor d...

Page 6: ...or podr a no funcionar Si la l mpara tiene m s de 60 W la distancia entre la l mpara y el sensor debe ser de al menos 60 cm PROBLEMAS Y SOLUCIONES La carga no funciona a Compruebe si la conexi n de la...

Page 7: ...tion d nergie approx 0 5W Charge nominale Max 1200W Hauteur d installation 1 8 2 5m 300W D tection de la vitesse de d placement 0 6 1 5m s FONCTION Peut identifier le jour et la nuit le consommateur p...

Page 8: ...r la position choisie avec la vis gonfl e voir figure 2 Branchez le c ble d alimentation dans la colonne des fils de connexion conform ment au sch ma des c bles de connexion Remettez le capot avant en...

Page 9: ...lez v rifier si la charge est bonne c Veuillez v rifier si les param tres de l clairage de travail correspondent la lumi re ambiante La sensibilit est mauvaise a Veuillez v rifier s il y a un obstacle...

Page 10: ...Umidade de Trabalho 93 RH Max 7min 2min Consumo de energia approx 0 5W Carga Nominal Max 1200W Altura de instala o 1 8 2 5m 300W Velocidade de Detec o de Movimento 0 6 1 5m s FUN O Pode identificar di...

Page 11: ...a 2 Conecte o fio de alimenta o na coluna de fios de conex o de acordo com o diagrama de fios de conex o Instale de volta a tampa frontal aperte o parafuso e ligue a alimenta o Ent o voc pode test lo...

Page 12: ...ambiente A sensibilidade fraca a Verifique se h algum obst culo na frente do detector que o afete para receber os sinais b Verifique se a temperatura ambiente est muito alta c Verifique se a fonte do...

Reviews: