background image

 

 

 

KDP7 180   

            0775871 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Instruction 

 

Welcome to use ST10F Infrared motion sensor! 

The  product  adopts  good  sensitivity  detector  and  integrated  circuit.  It  gathers  automatism, 

convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from 

human  as  control-signal  source  and  it  can  start  the  load  at  once  when  one  enters  detection 

field. It can identify day and night automatically. It is easy to install and used widely. 

SPECIFICATION: 

Power Source: 220-240V/AC                                  Detection Range: 180

°

 

Power Frequency: 50/60Hz                                    Detection Distance: 5-12m (<24

) adjustable

 

Ambient Light: <3-2000LUX (adjustable)              Working Temperature: -20~+40

 

Time Delay: Min.10sec

±

3sec                                Working Humidity: <93%RH 

                      Max.7min

±

2min                                  Power Consumption: approx 0.5W 

Rated Load: Max.1200W                                          Installation Height: 1.8-2.5m 

                                300W                                            Detection Moving Speed: 0.6-1.5m/s

 

FUNCTION : 

 

Can  identify day  and  night: The  consumer  can  adjust  working  state in different  ambient 

light. It can work in the daytime and at night when it is adjusted on the “sun” position (max). 
It can work in the ambient light less than 3LUX when it is adjusted on the “moon” position 

(min). As for the adjustment pattern, please refer to the testing pattern.   

 

SENS adjustable: It can be adjusted according to using location. The detection distance 

of low sensitivity could be only 5m and high sensitivity could be 12m which fits for large 

room. 

 

Time-Delay is added continually: When it receives the second induction signals within the 

first induction, it will restart to time from the moment. 

 

 

 

 

Good sensitivity                                                                        Poor sensitivity 

INSTALLATION ADVICE: 

As the detector responds to changes in temperature, avoid the following situations: 

 

Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors 

etc. 

 

Avoid  mounting  the  detector  near  heat  sources,  such  as  heating  vents,  air  conditioning 

units, light etc. 

Summary of Contents for KOBAN 0775871

Page 1: ...UNCTION Can identify day and night The consumer can adjust working state in different ambient light It can work in the daytime and at night when it is adjusted on the sun position max It can work in t...

Page 2: ...TEST Turn the SENS knob clockwise on the maximum Turn the TIME knob anti clockwise on the minimum Turn the LUX knob clockwise on the maximum sun Switch on the power the sensor and its connected lamp w...

Page 3: ...receive the signals b Please check if the ambient temperature is too high c Please check if the induction signal source is in the detection field d Please check if the installation height corresponds...

Page 4: ...de trabajo 20 40 Ajuste de tiempo Min 10sec 3sec Humedad de trabajo 93 RH Max 7min 2min Potencia consumida approx 0 5W Cargas soportadas Max 1200W Altura de instalaci n 1 8 2 5m 300W Detecci n de mov...

Page 5: ...ctada Quite la carcasa frontal directamente con un destornillador Figura 1 Afloje los tornillos en el terminal de conexi n y luego conecte el cable de alimentaci n al terminal de conexi n del sensor d...

Page 6: ...or podr a no funcionar Si la l mpara tiene m s de 60 W la distancia entre la l mpara y el sensor debe ser de al menos 60 cm PROBLEMAS Y SOLUCIONES La carga no funciona a Compruebe si la conexi n de la...

Page 7: ...tion d nergie approx 0 5W Charge nominale Max 1200W Hauteur d installation 1 8 2 5m 300W D tection de la vitesse de d placement 0 6 1 5m s FONCTION Peut identifier le jour et la nuit le consommateur p...

Page 8: ...r la position choisie avec la vis gonfl e voir figure 2 Branchez le c ble d alimentation dans la colonne des fils de connexion conform ment au sch ma des c bles de connexion Remettez le capot avant en...

Page 9: ...lez v rifier si la charge est bonne c Veuillez v rifier si les param tres de l clairage de travail correspondent la lumi re ambiante La sensibilit est mauvaise a Veuillez v rifier s il y a un obstacle...

Page 10: ...Umidade de Trabalho 93 RH Max 7min 2min Consumo de energia approx 0 5W Carga Nominal Max 1200W Altura de instala o 1 8 2 5m 300W Velocidade de Detec o de Movimento 0 6 1 5m s FUN O Pode identificar di...

Page 11: ...a 2 Conecte o fio de alimenta o na coluna de fios de conex o de acordo com o diagrama de fios de conex o Instale de volta a tampa frontal aperte o parafuso e ligue a alimenta o Ent o voc pode test lo...

Page 12: ...ambiente A sensibilidade fraca a Verifique se h algum obst culo na frente do detector que o afete para receber os sinais b Verifique se a temperatura ambiente est muito alta c Verifique se a fonte do...

Reviews: