KDP6

Wall presence detector

Helpful tlps for lnstallation.

Since the detector is in response to 
temperature change, please avoid 
the following conditions (Sea FIG.3):

• 

Avoid directing the 
detector toward the 
objects whose surfaces are 
highly reflective,such as 

mirror,monitor,etc

• 

Avoid mounting the detector 
near heat sources,such 
as heating vents,air 

conditioners,vents as 

dryers,lights,etc 

• 

Avoid aiming the detector 
toward the objects which may 
be swayed in the wind, such 

as curtain,tall plants,miniature 
garden, etc.

Summary of Contents for 0775869

Page 1: ...KDP6 Detector de presencia de pared Wall presence detector www grupotemper com ...

Page 2: ...emper com Índice Especificaciones PRECAUCIÓN Contenido del embalaje Descripción del producto Instalación y conexiones Selección del lugar de instalación Conexiones Uso y funcionamiento Ajuste de los selectores Test de paso Uso del protector de lente Resolución de problemas ...

Page 3: ...r Altura de instalación 2 0 3 0m altura recomendada 2 5m Rango de detección Hasta 270 Nivel crepuscular Desde apróx 5LUX hasta Ajuste de auto apagado Test desde apróx 6 seg hasta apróx 10 min y Ajuste de distancia Máx 10m Modo LED Apagado Advertencia Vigilancia Consumo Apróx 1W Temperatura de funcionamiento 20ºC a 45ºC Grado de protección IP44 La instalación y el montaje de equipos eléctricos siem...

Page 4: ...ie conductora Procure no abrir a menudo la carcasa protectora Apague el detector para cambiar las fuentes de luz Algunas marcas de bombillas pueden estallar y causar picos de tensión dañando el detector sin posibilidad de reparación Contenido del embalaje KDP6 110 KDP6 180 Icono Artículo Detector Protectores de lente Tornillos para madera Φ4x25 4mm arandelas de goma Manual Cantidad 1 2 2 1 KDP6 27...

Page 5: ...zación de las mismas El detector puede ser instalado en el techo en la pared esquinas y descansillos gracias a su soporte de pared Diseño único para abarcar varias direcciones de detección gracias a su cabezal giratorio multidireccional que le permite realizar ajustes arriba abajo hacia adelante o hacia atrás Tres ángulos de detección seleccionables para las diferentes necesidades de cada usuario ...

Page 6: ...gar de instalación Para lograr un patrón de detección óptimo se recomienda que instale su detector a una altura de entre 2 y 3 metros El área de detección puede alcanzar los 10 metros su cobertura interior circular abarca un radio de 0 5 metros Ángulo de detección KDP6 110 110 Ver FIG 2 A Ángulo de detección KDP6 180 180 Ver FIG 2 B Ángulo de detección KDP6 270 270 Ver FIG 2 C Montaje en pared Mon...

Page 7: ...red 7 Manual de instrucciones www grupotemper com Montaje en pared Montaje en techo Vista lateral Vista superior Vista lateral Vista superior Montaje en pared Montaje en techo Vista lateral Vista superior Vista lateral Vista superior ...

Page 8: ...iguientes condiciones Ver FIG 3 Evite dirigir el sensor hacia zonas u objetos de superficie muy reflectante como espejos monitores etc No instale el detector cerca de fuentes de calor tales como respiraderos de calefacción de aire acondicionado calefacciones luces etc Evite dirigir el detector hacia objetos que pudieran moverse con el viento como las cortinas plantas de cierta altura árboles peque...

Page 9: ...tector está configurado para montaje en pared Montaje en pared Retire la tapa frontal con un destornillador Introduzca la cabeza del destornillador en la ranura entre las dos tapas la frontal y la trasera y gírela 90º en dirección contraria a las agujas del reloj para retirar la tapa frontal Ver FIG 6 Preste atención en qué dirección camina cuando realice las pruebas El área de detección cuando se...

Page 10: ...y fije la carcasa trasera a la pared o al techo Por último coloque la tapa frontal y ajústela con los tornillos Ver FIG 8 Arandela de goma Tira de goma aislante Vista interior de la tapa frontal NOTA La tapa frontal lleva en su interior adherida una tira de goma no la retire y asegúrese de que su ajuste a la tapa es perfecto Ver FIG 8 Cuando coloquemos la tapa frontal en las ranuras un primer clic...

Page 11: ...ared lleva 8 orificios diseñados para sus diferentes aplicaciones Ver FIG 10 Rompa las hendiduras de los agujeros correspondientes a los cables e introdúzcalos a través de ellas Pestaña Ranura Ranura Pestaña Soporte para tornillo Soporte para tornillo Orificio para cable Orificio para cable Orificio para tornillo Orificio para tornillo ...

Page 12: ... fije el soporte con los tornillos para madera ver FIG 11 A y 11 B Fíjese en la indicación up hacia arriba para su colocación Consulte los puntos los esquemas de cableado para realizar la conexión de los cables y fije la tapa trasera al soporte ver FIG 12 por último coloque la tapa frontal Instalación en esquinas Instalación en juntas Arandela de goma ...

Page 13: ...horizontalmente hacia la derecha o hacia la izquierda 25º ver FIG 13 B Para conseguir un rango de detección perfecto asegúrese de que la línea hacia la izquierda B ver FIG 13 C y la línea hacia la derecha C Ver FIG 13 D se alinean con el saliente respectivamente para mantener la cabeza del detector en posición horizontal Línea A Saliente Línea B Línea A Línea C Saliente Montaje en techo Para insta...

Page 14: ...te hacia la derecha o hacia la izquierda un máx de 25º Ver FIG 15 B Preste atención y asegúrese que queda una cavidad a la izquierda A ver FIG 15 C en el borde de la cubierta interior horizontalmente ver FIG 15 D y también una cavidad a la derecha B ver FIG 15 E también en el borde de la cubierta interior horizontalmente ver FIG 15 F para obtener un ángulo de detección óptimo NOTA Si desea instala...

Page 15: ...ctor Si ajusta el selector TIME a la posición el tiempo mínimo de retardo es de 6 seg Si ajusta el selector TIME a la posición el tiempo máximo de retardo es de 10 min Si ajusta el selector TIME a la posición el minutero de escalera recibirá la señal cuando se active Ajuste el selector TIME a una posición entre y de acuerdo con sus deseos Ajuste del selector LUX Cuando el selector LUX está en la p...

Page 16: ...os los LED OFF Carga ON Todos los LED OFF Test de paso La finalidad de esta prueba es seleccionar el mejor lugar para la instalación del detector y la cobertura del mismo Gire el selector METER hasta el selector TIME a la posición Test luego realice el test de paso See FIG 18 Test de paso Inicio Final NOTA Una vez se conecta la alimentación el detector tarda unos 60 segundos en autoajustarse hasta...

Page 17: ... de 30º de detección Por ejemplo al instalar un detector a una altura de 2 5m el área de cobertura externa es Eliminada la capa C un sector de la zona de entre 0 5m y 4 5m quedará enmascarado Eliminando la capa B un sector de la zona de entre 0 5m y 7m quedará enmascarado Eliminando la capa A un sector de la zona de entre 0 5m y 10m quedará enmascarado La cobertura interna cubre un área circular d...

Page 18: ...de presencia de pared 18 Manual de instrucciones www grupotemper com KDP6 110 KDP6 180 KDP6 270 Ejemplo corte el protector de lente con unos alicates Patrón de detección Patrón de detección Patrón de detección Ranura ...

Page 19: ...or de presencia de pared 19 Manual de instrucciones www grupotemper com KDP6 110 KDP6 180 KDP6 270 Ejemplo corte el protector de lente con unos alicates Patrón de detección Patrón de detección Patrón de detección ...

Page 20: ...el modo TIME y que no hay interferencias que activen el detector 2 Manténgase fuera de la zona de cobertura del detector cuando realice la prueba 3 Compruebe que la carga y los cables están conectados correctamente La luz LED no se enciende 1 Se ha excedido el rango de detección 2 No hay alimentación 3 Cableado incorrecto 4 El selector TIME no está en modo Test 1 Camine dentro del rango de detecci...

Page 21: ...es puede restar sensibilidad al aparato En los días muy calurosos la menor sensibilidad se deberá a que la temperatura corporal se acercará a la ambiental En días de mucho frío la cantidad de ropa que nos ponemos y especialmente si nos tapamos la cara evitamos desprender calor corporal y al detector le será más difícil captar nuestra presencia Limpieza utilice únicamente un paño seco El uso de jab...

Page 22: ...KDP6 Detector de presencia de pared 22 Manual de instrucciones www grupotemper com ...

Page 23: ... com KDP6 Wall presence detector Contents Specification CAUTION Package contents Product description Installation and wiring Select a proper location Wiring Operation and funtion Knob setting Walk test Usage of lens shield Trouble shooting ...

Page 24: ...3 0M recommended installation height is approx 2 5M Detection Range up to 270 Lux Adjustment From approx 5LUX to Auto OFF Time Delay Test from approx 6 sec to approx 10 min and Meter adjustment Max 10M LED mode OFF Warning Watch Power Consumption Approx 1W Operating Temperature 20ºC to 45ºC Environmental Protection IP44 Installation and assembly of electrical equipment must be carried out by quali...

Page 25: ...ion A circuit breaker 250VAC 6A type C according to EN60898 1 of loadⅡshall be installed in the fixed wiring for protection Do not mount on conductive surface Do not open the enclosure frequently Turn off power when change the light sources High in rush current would be caused when bulbs of certain brands burned which might damage the unit permanently Package contents KDP6 110 KDO6 180 KDP6 270 ...

Page 26: ...he detector to guarantee complete surveillance or warning respectively Free installation for ceiling or wall mount and also can be used for corner recess installation with wall bracket Unique designed for multi direction sensing field rotatable detector head for up down forward sideward adjustments Selectable 3 versions of different detection angles for various purposes Variety load connections of...

Page 27: ...nstruction manual carefully before installation Select a proper location It is recommended to install the detector at the height of 2 3 m The detection range can reach up to 10M the inner coverage is a circular with radius of 0 5M Detection angle KDP6 110 110 See FIG 2 A Detection angle KDP6 180 180 See FIG 2 B Detection angle KDP6 270 270 See FIG 2 C ...

Page 28: ...28 Instructions manual www grupotemper com KDP6 Wall presence detector ...

Page 29: ...llowing conditions Sea FIG 3 Avoid directing the detector toward the objects whose surfaces are highly reflective such as mirror monitor etc Avoid mounting the detector near heat sources such as heating vents air conditioners vents as dryers lights etc Avoid aiming the detector toward the objects which may be swayed in the wind such as curtain tall plants miniature garden etc ...

Page 30: ... bracket or on the ceiling directly NOTE Motion detector KDP6 was set for wall mount before ex factory Wall mount Unscrew the front cover by screwdriver To lnsert the head screwdrlver blade lnto the gap between front cover and bottom case then rotate anti clockwise 90 to detach the front cover See FIG 6 Pay attention to the walking direction in the test proceeding the detection area cross to detec...

Page 31: ...washer and fix the bottom case on the wall or ceiling then cover up the front cover and tighten it with screws See FIG 8 NOTE DO NOT take off the rubber strip voluntarily and make sure it lies in the front cover perfectly See FIG 8 Click sound shows the upper hook has been fastened into slot See FIG 9 A and a second click sound shows the lower hook has been fastened into slot See FIG 9 B Please ma...

Page 32: ...l www grupotemper com KDP6 Wall presence detector Corner recess mount with bracket 8 knock out wall bracket is designed for various appllcatlon See FIG 1O break the knock out to feed the wires through the corresponding hole ...

Page 33: ...tor Break screw knock outs See FIG 10 then fix the wall bracket onto recess corner with wood screws See FIG 11 A FIG 11 B make sure UP mark upwards refer to wall mount to connect power cables and fix the bottom case on wall bracket See FIG 12 then assembly front cover ...

Page 34: ...x 15º vertically See FIG 13 A to shorten the detection range or turned leftward and roghtward max 25º horizontally See FIG 13 B In order to obtain optimum detection range it must be carreful ensure that leftward Line B See FIG 13 C and rightward Line C See FIG 13 D align bulge respectively to keep detector head horizontally Ceiling mount To rotate clockwise 180º of detector head for ceiling mount ...

Page 35: ...ertically See FIG 15 A to shorten the detection range or turned leftward and rightward max 25º horizontally See FIG 15 B It must be careful to ensure that aiming leftward hollowness A See FIG 15 C at the inner cover edge horizontally See FIG 15 D and also make sure rightward hollowness B see FIG 15 E at the inner cover edge horizontally see FIG 15 F in order to obtain optimum detection range NOTE ...

Page 36: ... TIME knob value at the position of the minimum delay time will be 6 sec Set TIME knob value at the position of the maximum delay time will be 10 min Set TIME knob value at the position of staircase time switch will receive 1 sec signal once KDP6 is triggered then the light ON 1 sec OFF 9 sec To adjust the TIME knob in between according to users desire LUX knob setting When setting the LUX knob to...

Page 37: ...coverage Turn METER knob to TIME knob to Test then conducting a walk test referring to step 4 1 See FIG 18 NOTE It takees approx 60 sec to warm up after power is supplied then enters into normal operation mode Test procedure Switch power on User must be within the detection coverage After the warming up period walk from outside across to the detection pattern until LED turns on for approx 2 sec ...

Page 38: ...e layers A B C each layer is divided into 3 small units a b c and the unit can mask an angle of approx 30º when mounting the detector at the height of 2 5M the outer coverage is Layer C eliminated mask the zone with a sector about from 0 5M to 4 5M Layer B eliminated mask the zone with a sector about from 0 5M to 7M Layer A eliminated mask the zone with a sector about from 0 5M to 10M The inner co...

Page 39: ...39 Instructions manual www grupotemper com KDP6 Wall presence detector KDP6 110 KDP6 180 KDP6 270 ...

Page 40: ...40 Instructions manual www grupotemper com KDP6 Wall presence detector KDP6 110 KDP6 180 KDP6 270 ...

Page 41: ...tly 1 To test the delay time specified on TIME knob and check detector is nuisance triggered if lighting device does not turn off as the delay time is up 2 Keep away from detection coverage to avoid activating detector while doing the test 3 Make sure load and wires are connected correctly LED does not turn on 1 Exceeding the detection range 2 No power supply 3 Wired incorrectly 4 TIME knob is not...

Page 42: ...sture collecting on the lens In very hot days the sensitivity may be less since high ambient temperature is close to body temperature In very cold days when heavy clothing is dresser especially the facial area is covered very little heat will be emitted from the body causing the unit to be less sensitivity Cleaning Wipe with dry cloth only Soap or rough cloth may damage the detector lens ...

Page 43: ...AL S L garantit cet apareil pour le durée de 2 annèes contre tout défault de fabrication Pour le service de garantie vous devez présenter ce reçu avec du ticket de caisse ou la facture TEMPER ENERGY INTERNATIONAL S L garantía este aparelho contra defeitos de fábrica ate 2 anos Para o serviço de garantia você deve apresentar este recibo com o recibo de compra ou fatura GARANTÍA WARRANTY GARANTIE GA...

Page 44: ...TEMPER ENERGY INTERNATIONAL S L Polígono industrial de Granda nave 18 33199 Granda Siero Asturias Teléfono 34 902 201 292 Fax 34 902 201 303 Email info grupotemper com Una empresa del grupo ...

Reviews: