PRG
PRG
SEL
SEL
rst
rst
mute
mute
OP1
OP2
HRS
MIN
SEC
Supply
Supply
OP2
OP2
OP1
OP1
Reset
Reset
T
T2
T2
T2
T2
T2
T2
T1
T1
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T2
T2
T1
T
T1
T1
T1
T1
T1
T1
dE-1
dE-2
It-2
dEIt
dP-1
cct
ddE
dd-2
on off
on off
24H
0
24:00
08:00 14:20
10:30 22:30
Parameter Function
Default Value
Range/Options
SET 1
Timing set-point 1
9000
0 to Timing Range
SET 2
Timing set-point 2
9000
0 to Timing Range
PASS
Password to access Program
3232
0 to 4999 for adjustable parameters
5000 to 9999 for parameter lock (view only)
MODE
Timing Mode selection
dE-1
dE-1: On-Delay + Instantaneous
ddE: 2 dependant On-Delays
dP-1: Delayed Pulse + Instantaneous
cct: Cycle Timer with adjustable on & off
dE-2: 2 independent On-Delays
It-2: 2 independent Intervals
dEIt: Independent On-Delay + Interval
dd-2: 2 independent Off-Delays
24H: 24 hour clock with 2 on & 2 off times
RNG1
Timing Range selection
SECS
SECS: 0.1 to 999.9 seconds -
NEW
SECS: 0 to 9999 seconds
RNG2
MINS: 0 to 9999 minutes
M-S: 0 to 99 mins 59 secs
H-M: 0 to 99 hours 59 mins
(23 h 59 m in 24H mode)
CNT
Direction of Timing Countdown uP
uP, dn
RSET
Reset options with RST button OFF
OFF: Reset button inactive
u on: Unconditional Restart
t on: Restart only after time-out
Euon: External Unconditional Restart -
NEW
Eton: External Restart only after time-out -
NEW
AST
Auto-Start mode -
NEW
ON
ON: Timer starts from switch on.
OFF: Timer waits for Start/Reset signal.
BEEP
Action of Buzzer at Time-out
OFF
OFF, on
BUTT
Allows beep on key press to be
ON
OFF, on -
NEW
switched on or off.
CLOC
Sets the 24 hour clock
00:00
0 to 23 hours 59 minutes
ON1, OFF1, On and Off time settings in
00:00
0 to 23 hours 59 minutes
ON2, OFF2 24 hour mode
Timing Modes
Program Parameters
Green LED indicators
showing energised outputs.
Green LED indicators
showing time range.
4 digit LED showing set times, process
time parameter messages and options.
Dimensions
Program Parameter Map
Supply
on
Timing starts
from 0 or nnnn
To change Set-point,
momentarily press
RST
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
Displays
SEt 1
Press
Displays value
with lsd (right)
digit flashing
Displays
0000
with msd (left)
digit flashing
Press or
until correct value,
then press
PRG
Press or
until required mode,
then press
PRG
Press or
until required range,
then press
Press or
to toggle between 'up'
& 'dn', then press
SEL
PRG
Press or
then press .
Repeat until code 3232,
then press
Press or
then press .
Repeat until correct
time, then press
Press or
then press .
Repeat until correct
time, then press
SEL
PRG
Press or
then press .
Repeat until required,
code then press
Displays value
with next digit
flashing
Repeat previous
step for next two
digits, then press
Times out to
value of SEt 1
& OP 1 led on
Press or switch
supply off then on.
Switch supply off, then
on, to start timing.
Displays
SEt 2
Displays
r nG2
For dual Timer
options
For dual Timer
options
For single
Timer options
For
single
Timer
options
Repeat as
for
SEt1
Repeat as
for
rnG1
To momentarily
view Set-points
press for SEt 1
or for SEt 2
PRG
To change other
Program parameters
press & hold
for > 4 secs.
Displays
PASS
Press
Press
Press
Press
Displays
nodE
Displays
dE-1
Displays
SECS
Displays
r nG1
Displays
cnt
Displays
uP
Displays
PASS
Displays
End
SEL
Press or
to select menu item
required, then
press
Displays
rSEt
Displays
OFF
Displays
3232
with msd (left)
digit flashing
Displays
CLOC
Alternately
displays
on-1 & off 1
times for 2 sec
Alternately
displays
on-2 & off 2
times for 2 sec
Displays
On-1
Displays
OFF1
Press
Press
Press
Press
Press
SEL
Press
SEL
Press
For all modes
except 24H
To set 24Hr times,
when selected
press
Press
SEL
SEL
PRG
Press or
to toggle between 'on'
& 'off', then press
PRG
Press or
to toggle between 'on'
& 'off', then press
PRG
Press or
to toggle between 'on'
& 'off', then press
Displays
bEEP
Displays
ASt
Displays
butt
Displays
OFF
Displays
On
Displays
On
Displays
00.00
with
msd (left)
digit flashing
Displays
00.00
with
msd (left)
digit flashing
Displays
00.00
with
msd (left)
digit flashing
Repeat sequence
for
On-2
and
OFF2
For 24H
mode
To momentarily
view 24H mode
on-1 & off 1
settings press
and hold
Repeat above
for on-2 & off 2
settings using
button
PRG
Press
PRG
PRG
Press
Press
Press
PRG
Press
PRG
Press
Note : These routines apply to
programming from default values.
Once another set-up has been
programmed, parameters will
start from the previous settings.
REF : Q03613 ISSUE 2
Specification
Ambient Temperature : 0 to 50 ºC.
Storage Temperature : -10 to 70 ºC.
Power Supply : ML : 12-24 Vac/dc +/- 10%.
MH : 110/240 Vac +/- 10%
Power Consumption : 3 VA Max.
Contact Rating OP1 : 8A @ 240Vac resistive.
OP2 : 8A @ 240Vac resistive.
Electrical Life : 200,000 operations
at rated load.
CE Approvals : EMC EN 50081-1
EN 50082-1
Low Voltage EN 61010-1
Other Products
Versions of this timer are also available in a 1/16 DIN
package (48 x 48mm) -
TE48
- and a 33 x 75 mm panel
mounting package -
TT32.
This timer has a matching range of temperature controls
- the
IRDR
- covering simple on/off and proportional
control right up to sophisticated autotuning PID control.
In addition Tempatron can supply a broad range of
industrial control products from temperature and
proximity sensors, timers, controllers, chart recorders,
solid state relays and heating elements. Call our sales
office or visit our internet web site for more details.
Press
PRG
Press
PRG
Press
PRG
Press
Press
PRG
PRG
Displays time
of day and
continues timing
SEL
PRG
Press or
then press .
Repeat until correct
time, then press
PRG
Press
Press
PRG
Timing starts
from 0 or nnnn
N
Front Panel Functions
Programming/set up
buttons (see over for
operating details).
8
8
70
65
Panel cut-out
70 x 45
15
Wiring Diagram
1 2 3 4 5 6
7 8 9
10 11 12 13
OP1
OP2
Neutral
110 Vac
240 Vacl
Reset
/ Start
Hold
3.0V
0V
24hr battery backup
(optional - see note 7)
8A @ 240Vac
12/24 Vac/dc
ML type
MH type