TMP
Oil Furnaces
–
Furnace Manual
670-000-004/1010
25
12
Dimensions and ratings
Figure 5
Model TMP dimensional data – ALL DIMENSIONS IN INCHES
Flue pipe
Width
Depth
Height
Width
Depth
Width
Depth
diam.
A
B
C
J
K
R
S
TMP-105
21
21
57
19 3/4
19 3/4
19 3/4
19 3/4
5
Return air
(side)
Model
Furnace casing
Warm air supply
(top)
Maximum heating
Filter
Electrical
Minimum
Maximum
Ship
temperature rise
quantity
load
ampacity for
fuse size
weight
(
o
F)
and size
(amps)
wiring sizing
(amps)
(pounds)
TMP-105
55 - 70
(1) 20 X 20
115 - 60 - 1
12.2
13.7
15
202
Model
Volt - Hertz - Phase
DNS-0908 Rev. A
(BTU/h)
(BTU/h)
(GPH)
@ 0.25" WC
@ 0.50" WC
(tons)
@ 0.25" WC
@ 0.50" WC
70,000
58,000
0.50
81.5
GT10-10
1/3
Med. - Low
Med. - Low
3
800
770
88,200
72,500
0.63
81.0
GT10-10
1/3
Med. - Hi
Med. - Hi
3
1060
970
105,000
85,200
0.75
80.2
GT10-10
1/3
High
High
3
1350
1210
Direct-drive units
TMP-105
Blower speed
Maximum
cooling
capacity
Blower CFM
Installed
nozzle
AFUE
Blower
size
Blower
motor HP
Model
Input
Output Firing rate