Mantels

The height that a combustible mantel is fitted above the 

fireplace is dependent on the depth of the mantel. This 

also applies to the distance between the mantel leg (if 

fitted) and the fireplace.
For correct mounting height and width, refer to Figure 

2a and 2b.
The distances and reference points are not affected by 

the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at 

any height and width around the appliance.
When using paint or lacquer to finish the mantel, such 

paint or lacquer must be heat-resistant to prevent dis-

coloration.

J

F

G

H

I

CFM164a

Mantel Leg Chart

06/22/01   sta

Black 

Surround 

Face

CFM164a

CFM170

DV Builder Front 

View

O

N

M

L

K

Side of Combustion 

Chamber

CFM170

Fig. 2b

  Combustible mantel leg minimum installation.

 

 

Mantel 

 

Mantel Leg from Side

  Ref. 

Leg Depth 

Ref. 

of Comb. Opening

 

14"  (356mm) 

14"  (356mm)

 

12"  (305mm) 

12"  (305mm)

 

10"  (254mm) 

10"  (254mm)

 

8"  (203mm) 

8"  (203mm)

 

1

¹⁄₂

"  (38mm) 

1

¹⁄₂

"  (38mm)

Framing

1.  Choose fireplace location.
2.  Place fireplace into position.
3.  Frame in the fireplace with a header across the top. 

It is important to allow for finished face when setting 
the depth of the frame.

Four (4) nailing flanges are supplied with the fireplace 

(found on the fireplace hearth). To level the box and 

secure it firmly in place, remove the nailing flanges from 

the hearth and install at the sides of the fireplace as 

shown in Figure 3.

A B C D E

V

W

X

Y

Z

CFM146c

Electric Mantel 

Chart

1/22/04  djt

   

Mantel Shelf 

 

Mantel from Top       

  Ref. 

Depth 

Ref.  of Comb. Chamber

  V 

14"  (356mm) 

25"  (635mm) 

  W 

12"  (305mm) 

23"  (584mm) 

  X 

10"  (254mm) 

21"  (533mm) 

  Y 

8"  (203mm) 

19"  (483mm) 

  Z 

1

¹⁄₂

"  (38mm) 

15"  (381mm) 

Wall

Top of Combustion Chamber

CFM146b

Fig. 2a

   Combustible mantel minimum installation.

Mantel Clearances

Mantel Leg

Summary of Contents for TBREF36

Page 1: ...FORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www m...

Page 2: ...s 5 Framing 5 Finishing 6 Locating your Electric Fireplace 6 Clearance to Combustibles 6 Hearth 6 Cabinet Installations 6 Main Power Wall Switch Wiring 6 120 Volt Wall Switch Wiring Installation 6 240 Volt Wall Switch Wiring Installation 7 120 240 Volt Wall Mounted Thermostat Wiring 7 Installation Cautions 7 120 Volt Unit Installation 8 120 Volt NH Unit Installation 8 240 Volt Unit Installation 8 ...

Page 3: ...t surfaces e g beds where openings may become blocked 11 This appliance has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored This fireplace should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung in the area of it 12 Use this appliance only as described in this manual Any other u...

Page 4: ...mensions Fig 1 Fireplace specifications and framing dimensions Ref TBREF36 TBREF36NH A 40 1016mm B 36 914mm C 36 914mm D 21 533mm E 7 191mm F 19 502mm G 14 356mm H 27 698mm Framing Dimensions J 36 927mm K 41 1041mm L 14 356mm M 37 953mm N 54 1372mm O 27 686mm Electrical Specifications Voltage 120 Volt 120 Volt NH 240 Volt Total Amps 13 Amps 2 Amps 12 9 Amps Total Watts 1550 Watts 240 Watts 3100 Watt...

Page 5: ...le mantel leg minimum installation Mantel Mantel Leg from Side Ref Leg Depth Ref of Comb Opening F 14 356mm K 14 356mm G 12 305mm L 12 305mm H 10 254mm M 10 254mm I 8 203mm N 8 203mm J 1 38mm O 1 38mm Framing 1 Choose fireplace location 2 Place fireplace into position 3 Frame in the fireplace with a header across the top It is important to allow for finished face when setting the depth of the frame Fo...

Page 6: ...which allow fast convenient installation of your fireplace against existing walls Main Power Wall Switch Wiring To reduce the risk of fire electrical shock and personal injury before attempting maintenance or service disconnect all power to the fireplace at the main service panel 120 Volt Wall Switch Wiring Installation A qualified electrician must perform any electrical wiring of this appliance For C...

Page 7: ...ntenance or ser vice to reduce risk of fire electrical shock and personal injury disconnect all power to the fireplace at the main service panel NOTE Wiring of the wall thermostat must be com pleted prior to the installation of the unit Use a single pole thermostat rated for 120 240 Volt operation When installing the wall thermostat make sure to turn the heater control inside fireplace all the way cl...

Page 8: ... 240 Volt Unit Installation 1 Locate the voltage selection switch under the logset on the left front corner of the unit 2 Check the switch position to ensure it is in the 240 Volt position 3 Loosen the screws securing the junction box cover and remove the cover 4 Remove knockouts in the box cover to use the cable clamp Resetting the Temperature Cutout Switch To reduce the risk of fire electrical sh...

Page 9: ...Volt 60 Watt E 12 socket base small base chandelier candle type light bulbs These lights are located under the ember bed of the unit Do not exceed 60 Watts per bulb Use of higher rated bulbs may result in fire caus ing property damage personal injury or loss of life NOTE For the sake of convenience you may wish to consider replacing all the light bulbs if one of them burns out 1 Turn OFF the power ...

Page 10: ...3 20 WHITE 10 BLACK 3 BLACK 4 BLACK BLACK BLACK RED WHITE FP1541 BREF heat wiring 1 05 Component Identification 1 Heater Element 9 Light Bulb 2 Limit Control 175 20 DIF 10 Light Socket w Wiring Assembly 3 Relay Switching 120V 50 60Hz 11 Cable Tie Nylon 6 1 Black 4 Fan Heater Motor 12 Bushing Snap Split 1 5 Thermostat 13 Closed End Splice 2 18 Ga Wire 6 Switch Rocker 14 CFM Wire Req d BREF36 7 Switc...

Page 11: ...embly 5 Cable Tie Nylon 6 1 Black 6 CFM Wire req d Electrical Wiring Diagram without Heater and Integral Remote Control FP1540 Fig 7 Wiring diagram for models without heat 5 WHITE 2 BLACK L1 N G 3 BLACK 6 WHITE 1 BLACK 7 WHITE 4 BLACK BLACK WHITE BLACK WHITE MOTOR FLAME 3 5 4 2 1 8 WHITE I O 3 2 1 FP1540 BREF no heat wiring 1 05 ...

Page 12: ... the room Turn the knob clockwise from the OFF position to place the heater into operation The further the knob is rotated clockwise the higher the set point temperature Turn the knob counterclockwise to lower the set point temperature Turn it all the way counterclockwise to turn the heater function OFF Operating Instructions NOTE The device complies with Part 15 of the FCC Rules Operation is subj...

Page 13: ...ucts reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice TBREF36 TBREF36NH Electric Fireplace TBREF36 TBREF36NH 5 4 3 6 7 2 8 9 11 12 13 15 16 17 4758 BREF parts 1 05 14 20 1 ...

Page 14: ... 10007639 20 Screen Assembly 7554338 7554338 21 Screen Rod 10007433 10007433 22 One Piece Screen Pull 2 per Fireplace 7554239 7554239 23 Cable Clip 4 per Fireplace 7512135 7512135 Accessories The following accessories for these appliances are available from your local CFM Specialty Home Products distributor NOTE Each accessory comes with a separate in stallation instruction for mounting to the par...

Page 15: ...SE CFM Specialty Home Products aux présentes nommée la Société garantit votre nouveau foyer électrique Majestic Fireplaces contre tous défauts de fabrication et de matières premières pour une période d un an à compter de la date d installation sujet aux conditions et limitations suivantes 1 Le foyer electrique doit être installé par un entrepreneur de service autorisé et compétent Il doit être ins...

Page 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www temcofireplaces com CFM Specialty Home Products ...

Reviews: