TEMA TELECOMUNICAZIONI
AD630VoIP SIP 25W / PoE Horn
MAS-AD630-REV02EN
Page 21 of 48
9.4. SIP Parameters
Once the network parameters have been set correctly, you must configure the connection with the VoIP SIP PBX:
•
SIP server address
: specify the IP address of the SIP PBX to which AD630 should connect.
•
Port
: is the port number of the SIP PBX with which AD630 must operate. Generally it is the 5060, but some
stations use a different port.
•
Domain
: enter the domain to which register the system.
•
Outbound proxy
: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•
Local SIP port
: generally the 5060 port is used, but it is possible to specify a different number (i.e. for
particular routing tables).
•
User/password
: credentials for the registration of the extension (which obviously must have been already
created on the PBX).
•
Expiration
: indicates how many seconds the device should check the correct registration of the client.
•
2
ND
SIP account
: this account is used for “Night ringer”. It is possible to configure, in the PBX, a ringer
group used in night mode, so if the doorphone is put in the same group, it will play the ringer message
when receiving an incoming call, without answering.
•
Password
: the second account registration password.
•
Volume
: it is possible to set the volume used to reproduce the sound of Night Ringer. It is also the volume
used to reproduce the prerecorded announcements.
•
Amplifier:
no function on AD630.
•
Relay 1
: for the entire duration of the call it is possible to keep the relay1 activated. It can be used for
example to turn on a flash, a lamp, etc.
•
Relay 2
: for the entire duration of the call it is possible to keep the relay2 activated. It can be used for