TEMA TELECOMUNICAZIONI SRL
AC-16Q / AC-16R Analog telephone line alarm
MAS-AC-16-REV03EN
Page 9 of 10
7. PROGRAMMING
7.1.
Programming the number to contact for notice
To access to the AC-16 programming, from the idle state, press the external silencing button (if
connected) for a while or press the PROGRAM button inside the plastic case of the device. The
condition of the system ready for programming is signaled by the unique led on the card placed
inside the case. For all the time that the led stays on (15 seconds) the device can be called to his
number and AC-16 will answer to allow its programming.
The call must be made from another extension number, using a standard DTMF telephone. At the
response of AC-16 and after a beep is heard, introduce the code of the programming password
(pwd = *1235), wait for the confirmation beep and insert the phone number that must be
programmed. Once the number was inserted, press # to confirm and wait for another confirmation
beep. At this point it is possible to select the alarm notification mode by choosing: the digit "0" for
alarm notification with simple tone, the digit "1" for alarm notification with voice message 1, the digit
"2" for alarm notification with voice message 2, the digit "3" for alarm notification with voice
message 1+2 (concatenated). Wait for the confirmation beep. The memory space for voice
messages of 16 seconds is logically divided into two sections of 8 seconds each, where the first
section contains the message 1 and the second one contains the message 2.
Choose between the digits 0-1-2-3 the value for the desired time of alarm notification, 0=30”,
1=60”, 2=90”, 3=120” and hang up.
Example:
-
press the internal reset button
(or external if connected), the led will light
-
call the extension number
where AC-16 is connected within 15 seconds
- heard a beep,
enter * 1235
to access to the number programming
- heard the beep for confirm of entering programming,
enter the number phone to
alert
, press
#
to confirm and wait for the confirmation beep
- introduce now the digit "
0
" or "
1
" or "
2
" or "
3
" to program the desired alarm
notification mode (0=tone, 1=message 1, 2=message 2; 3=Message 1 +2, wait for
the confirmation beep
-introduce
now
the
digit
"
0
"
or
"
1
"
or
"
2
"
or
"
3
"
to
program
how long AC-16 will notify the alarm before hanging for time out
(0=30 seconds, 1=60 seconds, 2=90 seconds, 3=120 seconds).
- wait for the confirmation beep, AC-16 will close the call and will retain the
introduced parameters
It is possible to input the character * (star) in the number to call to get a dialing pause of 500
milliseconds for each * digit introduced.
The maximum field length of the number to call is fixed at 20 digits (including * digits).
If you get into programming and you do not make the introduction of a new number to call or do not
end with
#
the number introduced, it is like not having done any programming, and the old number
will remain in memory.
If, however, after confirming the entered number with the
#
character and heard the beep of
confirmation will not be introduced additional characters, there will be no change to the previous
programmed mode of how AC-16 will notify the alarm (tone or voice message).
Finally, if you also confirms how AC-16 will notify the alarm will not be introduced additional
characters, there will be no change to the previous programmed time alarm notification.
During programming, AC-16 waits 15 seconds from the last command received, then close the
communication breaking down the programming state.