Instructions for use and maintenance
Electric motors 75-200 V DC
Q4 / Q7 MOTOR CONNECTION
POSITIVE MOTOR (+)
L
NEGATIVE MOTOR (-)
N
POSITIVE D.T. (+)
BLUE CABLE
NEGATIVE D.T. (-)
RED CABLE
R3 / R6 MOTOR CONNECTION
POSITIVE MOTOR (+)
U1
NEGATIVE MOTOR (-)
V1
POSITIVE D.T. (+)
W2
NEGATIVE D.T. (-)
U2
PMB MOTOR CONNECTION
POSITIVE MOTOR (+)
RED / PIN 1
NEGATIVE MOTOR (-)
BLACK / PIN 2
POSITIVE D.T. (+)
BLUE CABLE
NEGATIVE D.T. (-)
RED CABLE
PMM, PML, PMX, D2 MOTOR CONNECTION
POSITIVE MOTOR (+)
L / RED CABLE
NEGATIVE MOTOR (-)
N / BLACK CABLE
POSITIVE D.T. (+)
BLUE CABLE
NEGATIVE D.T. (-)
RED CABLE
PMR, PMT, D4 MOTOR CONNECTION
POSITIVE MOTOR (+)
W2
NEGATIVE MOTOR (-)
U1
POSITIVE D.T. (+)
V1
NEGATIVE D.T. (-)
U2
MP62 / MP71 / MP80 MOTOR CONNECTION
POSITIVE MOTOR (+)
RED CABLE
NEGATIVE MOTOR (-)
BLACK CABLE
POSITIVE D.T. (+)
BLUE CABLE
NEGATIVE D.T. (-)
RED CABLE
ALTERNATOR AND/OR BRAKE CONNECTION
ALTERNATOR: it is possible to connect both positive and negative poles.
STANDARD BRAKE (SPRING NEGATIVE): it is possible to connect both positive and negative poles without distinction.
POSITIVE AND PERMANENT MAGNET BRAKE: Follow the connection diagram attached to the motor.
NB: All motors are equipped with a clamp or screw for grounding highlighted by
the symbol:
The direction of rotation of the motor is the conventional one (clockwise rotation seen
power side) according to EN 60034-8.
WARNING:
-
Verify that the transformers used are safe according to IEC 14/6.
-
Ensure that connections to electrical sockets are protected from
flooding and moisture.
-
For motor connections and accessories use cables of
appropriate size, with shielding and ground conductor.
-
Failure to comply with the requirements may cause significant damage to the motor.
Page
11
of
19