background image

 

 

VISCA IN (RS232) PORT 

 

 

 
 
 
 
 
 
 
 

 

     

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
SERIAL PORT CONFIGURATION: 
                                   

 

 
 

 

 

 
 
 
 
 
 
 
 
 
 
 

No. 

Function 

DTR 

DSR 

TXD 

GND 

RXD 

IR OUT 

VISCA IN &RS485 Connection 

Camera VISCA IN 

RS485 

DTR                     

 

DSR                     

 

TXD                 

 

GND                    GND 

RXD             

 

A(+)                    A(+) 

IR OUT 

 

B(-)                        B(-) 

VISCA IN &DB9 Connection 

Camera VISCA IN 

Windows DB-9 

DTR                     

DSR 

DSR                     

DTR 

TXD                 2 

RXD 

GND                   

GND 

RXD              3 

TXD 

A(+)                 

 

IR OUT 

 

 

B(-)                       

 

 

Parameter 

Value 

Parameter 

Value 

Baud rate 

2400/4800/9600/115200 

Stop Bit 

1bit 

Start Bit 

1 bit 

Verify Bit 

None 

Date Bit 

8 bit 

 

 

Summary of Contents for TLC-1000-U3-10

Page 1: ...USB3 0 HD Video Camera User Manual Version V1 0 English...

Page 2: ...1...

Page 3: ...QUICK START 4 PRODUCT HIGHLIGHTS 5 PRODUCT SPEC 5 CAMERA INTERFACE 6 CAMERA DIMENSION 6 IR REMOTE CONTROLLER 7 LEARNING FUNCTION 8 VISCA IN RS232 PORT 9 VISCA PROTPCOL 10 PELCO D PROTOCOL 16 PELCO P...

Page 4: ...installation 7 Do not dismantle the camera housing and cover For any service please contact authorized technicians 8 RF cable and control cable should be individually shielded and cannot be substitute...

Page 5: ...F OFF Updating mode 2 ON OFF Debugging mode 3 OFF ON Undefined 4 ON ON Working mode Function IR CODE TYPE SW 3 SW 4 Instruction 1 OFF OFF Off Close IR receiver 2 ON OFF Undefined 3 OFF ON SEJIN 4PPM C...

Page 6: ...signal and pass these IR control signal to the codec s IR receiver via VISCA IN port Multi language OSD menu English Chinese PRODUCT SPEC Video Format USB3 0 1080P30 25 720P60 50 30 25 15 704 576P30 6...

Page 7: ...amera Lens 5 Dial Switch 9 USB3 0 Port 2 Camera Base 6 Tripod Screw Hole 10 12VDC Power Input 3 IR Receiver Panel 7 Installation Hole 11 Power Indicator light red 4 Indicator Light 8 RS232 VISCA IN Po...

Page 8: ...that was set Green button Codec power button need to learn the button coding Blue button TV power button need to learn the button coding Focus Left Manual focus only valid under manual focus model Zoo...

Page 9: ...eed to be learned Press the Home 0 buttons simultaneously to exit and save all remote data If the button learning fails the camera will enter normal working mode after 15seconds LED will extinguish 3...

Page 10: ...Camera VISCA IN RS485 1 DTR 2 DSR 3 TXD 4 GND GND 5 RXD 6 A A 7 IR OUT 8 B B VISCA IN DB9 Connection Camera VISCA IN Windows DB 9 1 DTR 6 DSR 2 DSR 4 DTR 3 TXD 2 RXD 4 GND 5 GND 5 RXD 3 TXD 6 A 7 IR...

Page 11: ...nd Function Command Packet Note AddressSet Broadcast 88 30 01 FF Address setting IF_Clear Broadcast 88 01 00 01 FF I F Clear CAM_Power On 8x 01 04 00 02 FF Power ON OFF Off 8x 01 04 00 03 FF CAM_Zoom...

Page 12: ...l Control mode Shutter Priority 8x 01 04 39 0A FF Shutter Priority mode Iris Priority 8x 01 04 39 0B FF Iris Priority mode Bright 8x 01 04 39 0D FF Bright mode Manual control CAM_Shutter Reset 8x 01 0...

Page 13: ...2 FF Image Flip Vertical ON OFF Off 8x 01 04 66 03 FF CAM_MountMode UP 8x 01 04 A4 02 FF Mount Up Down 8x 01 04 A4 03 FF Mount Down CAM_Saturation Direct 8x 01 04 A1 00 00 00 0p FF 0 0x0E CAM_2D Noise...

Page 14: ...YYY Pan Limit Position TBD ZZZZ Tilt Limit Position TBD Clear 8x 01 06 07 01 0W 07 0F 0F 0F 07 0F 0F 0F FF Part3 Inquiry Command Command Command Packet Return Packet Note CAM_PowerInq 8x 09 04 00 FF y...

Page 15: ...sionInq 8x 09 00 02 FF y0 50 ab cd mn pq rs tu vw FF IR_Transfer 8x 09 06 1A FF y0 50 02 FF On y0 50 03 FF Off IR_Receive 8x 09 06 08 FF y0 50 02 FF On y0 50 03 FF Off IR_ReceiveReturn y0 07 7D 01 04...

Page 16: ...500 2 F11 18 1 3000 1 2500 3 F9 6 17 1 2000 1 1750 4 F8 16 1 1500 1 1250 5 F6 8 15 1 1000 1 1000 6 F5 6 14 1 725 1 600 7 F4 8 13 1 500 1 425 8 F4 12 1 350 1 300 9 F3 4 11 1 250 1 215 10 F2 8 10 1 180...

Page 17: ...0x00 SUM Zoom Out 0xFF Address 0x00 0x40 0x00 0x00 SUM Focus Far 0xFF Address 0x00 0x80 0x00 0x00 SUM Focus Near 0xFF Address 0x01 0x00 0x00 0x00 SUM Set Preset 0xFF Address 0x00 0x03 0x00 Preset ID...

Page 18: ...F XOR Zoom Out 0xA0 Address 0x00 0x40 0x00 0x00 0xAF XOR Focus Far 0xA0 Address 0x00 0x80 0x00 0x00 0xAF XOR Focus Near 0xA0 Address 0x01 0x00 0x00 0x00 0xAF XOR Set Preset 0xA0 Address 0x00 0x03 0x00...

Page 19: ...s menu Press it continuously to exit the OSD menu Before exiting will show up a window to remind whether need to save all settings use left and right button to set 5 OSD Menu List Defaulted Setting CA...

Page 20: ...IS AUTO SHUT TIME Set shutter speed 1 8 1 10000 Only available under MANU or SHUT mode 1 100 IRIS Set iris value 0 13 only available under MANU or IRIS mode 10 GAIN Set gain value 0 15 only available...

Page 21: ...ition 479 LINE START Set current mask zone s line start position 0 LINE END Set current mask zone s line end position 539 RETURN Return to previous menu D N MODE D N MODE Set D N mode DAY NIGHT AUTO D...

Page 22: ...upport standard UVC interface UVC Property Corresponded VISCA Command PU_BACKLIGHT_COMPENSATION_CONTROL 8x 01 04 33 02 FF CY_FX_UVC_PU_BRIGHTNESS_CONTROL 8x 01 04 A4 00 00 0p 0q FF CY_FX_UVC_PU_CONTRA...

Page 23: ...22...

Page 24: ...23...