Teltonika FMB910 Quick Manual Download Page 14

 

14 

FMB910 | 

Wiki 

Safety information 

This message contains information on how to operate FMB910 safely. By 

following these requirements and recommendations, you will avoid 

dangerous situations. You must read these instructions carefully and 

follow them strictly before operating the device!  

 

The device uses SELV limited power source. The nominal voltage is 

+12 V DC. The allowed voltage range is +6 ...+30 V DC. 

 

To avoid mechanical damage, it is advised to transport the device in 

an impact-proof package. Before usage, the device should be placed 

so that its LED indicators are visible. They show the status of device 

operation. 

 

When connecting the (1x5) cables to the vehicle, the appropriate 

jumpers of the vehicle power supply should be disconnected.  

 

Before dismounting the device from the vehicle, the 1x5 connection 

must be disconnected. 

 

The device is designed to be mounted in a zone of limited access, 

which is inaccessible to the operator. All related devices must meet 

the requirements of EN 60950-1 standard. 

 

The device FMB910 is not designed as a navigational device for boats. 

 

Do not disassemble the device. If the device is 
damaged, the power supply cables are not isolated or 
the isolation is damaged, DO NOT touch the device 
before unplugging the power supply. 

 

All wireless data transferring devices produce 
interference that may affect other devices which are 
placed nearby.

 

 

The device must be connected only by qualified 
personnel.

 

 

The device must be firmly fastened in a predefined 
location. 

 

 

The programming must be performed using a PC 
with autonomic power supply. 

 

Installation and/or handling during a lightning storm 
is prohibited. 

 

The device is susceptible to water and humidity. 

 

Risk of explosion if battery is replaced by an incorrect 
type. Dispose of used batteries according to the 
instructions.

 

 

Battery should not be disposed of with general 
household waste. Bring damaged or worn-out 
batteries to your local recycling center or dispose 
them to battery recycle bin found in stores.

 

Summary of Contents for FMB910

Page 1: ...Quick Manual v1 1 Track trace device FMB910...

Page 2: ...he battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic char...

Page 3: ...3 FMB910 Wiki Know your device Figure 1 FMB910 device view...

Page 4: ...IPTION 1 VCC 6 30 V DC Power supply 6 30 V DC 2 GND Ground pin 3 DIN 1 Digital input channel 1 DEDICATED FOR IGNITION INPUT 4 AIN 1 Analog input channel 1 Input range 0 30 V DC 5 DOUT 1 Digital output...

Page 5: ...5 FMB910 Wiki Figure 3 FMB910 Wiring scheme Wiring scheme 1 Automotive relay 1...

Page 6: ...isabled or read Security info how to enter it later in Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 4 Connect internal back up battery 5 Attach device cover ba...

Page 7: ...lick Next in driver installation window 4 In the following window click Install button 5 Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to co...

Page 8: ...1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update fi...

Page 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Page 10: ...dule is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable in the fuse box 3 A 125 V external fuse shall be used Connecting ignit...

Page 11: ...ellites visibility Characteristics Basic characteristics Table 4 Basic characteristics MODULE Name Teltonika TM2500 Technology GSM GPRS GNSS BLUETOOTH GNSS GNSS GPS GLONASS GALILEO BEIDOU SBAS QZSS DG...

Page 12: ...C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP54 Battery charge temperature 0 C to 45 C Battery discharge temperature 20 C t...

Page 13: ...DIN1 47 k Input voltage Recommended Operating Conditions 0 Supply voltage V Input Voltage threshold DIN1 3 9 V ANALOG INPUT Input voltage Recommended Operating Conditions 0 30 V Input resistance 150...

Page 14: ...which is inaccessible to the operator All related devices must meet the requirements of EN 60950 1 standard The device FMB910 is not designed as a navigational device for boats Do not disassemble the...

Page 15: ...ll User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste Hereby Teltonika decla...

Page 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Reviews: