![Teltonika FMB230 Quick Manual Download Page 14](http://html1.mh-extra.com/html/teltonika/fmb230/fmb230_quick-manual_1084772014.webp)
14
Ignition detection
Digital Input 1, Accelerometer, External
Power Voltage, Engine RPM (CAN Adapters,
OBDII dongle)
Electrical characteristics
Table 6 Electrical characteristics
CHARACTERISTIC DESCRIPTION
VALUE
MIN.
TYP.
MAX.
UNIT
SUPPLY VOLTAGE
Supply Voltage (Recommended Operating
Conditions)
+10
+30
V
DIGITAL OUTPUT (OPEN DRAIN GRADE)
Drain current (Digital Output OFF)
120
µA
Drain current (Digital Output ON,
Recommended Operating Conditions)
0.1
0.5
A
Static Drain-Source resistance (Digital Output
ON)
400 600
mΩ
DIGITAL INPUT
Input resistance (DIN1)
47
kΩ
Input resistance (DIN2)
38.45
kΩ
Input resistance (DIN3)
150
kΩ
Input voltage (Recommended Operating
Conditions)
0
Supply
voltage
V
Input Voltage threshold (DIN1)
7.5
V
Input Voltage threshold (DIN2)
2.5
V
Input Voltage threshold (DIN3)
2.5
V
ANALOG INPUT
Input voltage (Recommended Operating
Conditions), Range 1
0
+10
V
Input resistance, Range 1
38.45
kΩ
Measurement error on 12V, Range 1
0.9
%
Additional error on 12 V, Range 1
108
mV
Measurement error on 30 V, Range 1
0.33
%
Additional error on 30 V, Range 1
88
mV
Input Voltage (Recommended Operating
Conditions), Range 2
0
+30
V
Input resistance, Range 2
150
kΩ
Measurement error on 12 V, Range 2
0.9
%
Additional error on 12 V, Range 2
108
mV
Measurement error on 30 V, Range 2
0.33
%
Additional error on 30 V, Range 2
88
mV
OUTPUT SUPPLY VOLTAGE 1-WIRE
Supply voltage
+4.5
+4.7
V
Output inner resistance
7
Ω
Output current (U
out
> 3.0 V)
30
mA
Short circuit current (U
out
= 0)
75
mA
NEGATIVE INPUT
Input resistance
38.45
kΩ
Input voltage (Recommended Operating
Conditions)
0
Supply
voltage
V
Input voltage threshold
0.5
V
Sink current
180
nA