POWER

 

Input voltage range 

10-30 V DC with overvoltage protection 

Back-up battery 

170 mAh Li-Ion battery 3.7 V (0.63 Wh) 

Internal fuse 

3 A, 125 V 

Power consumption 

At 12V < 6 mA (

Ultra Deep Sleep

) 

At 12V < 8 mA (

Deep Sleep

) 

At 12V < 11 mA (

Online Deep Sleep

) 

At 12V < 19 mA (

GPS Sleep

) 

At 12V < 34 mA (nominal no load) 
At 12V < 1.5 A Max. (with full Load/Peak) 

BLUETOOTH

 

Specification 

4.0 + LE 

Supported peripherals 

Temperature and Humidity sensor

Headset

OBDII dongle

, Inateck Barcode 

Scanner, Universal BLE sensors support

 

INTERFACE

 

Digital Inputs 

Digital Outputs 

Analog Inputs 

CAN Adapter inputs 

1-Wire  

GNSS antenna 

External (MMCX connector) 

GSM antenna 

Internal High Gain 

USB 

2.0 Micro-USB 

LED indication 

2 status LED lights 

SIM 

Dual SIM 

Memory 

128MB internal flash memory 

 

PHYSICAL SPECIFICATION

 

Dimensions 

65 x 56,6 x 20,6 mm (L x W x H) 

Weight 

55 g 

OPERATING ENVIRONMENT

 

Operating temperature (without 
battery) 

-40 °C to +85 °C 

Storage temperature (without 
battery) 

-40 °C to +85 °C 

Operating humidity 

5% to 95% non-condensing 

Ingress Protection Rating 

IP41 

Battery charge temperature 

0 °C to +45 °C 

Battery discharge temperature 

-20 °C to +60 °C 

Battery storage temperature 

-20 °C to +45 °C for 1 month 
-20 °C to +35 °C for 6 months 

FEATURES 

Sensors 

Accelerometer 

Scenarios 

Green Driving

Over Speeding detection

Jamming detection

GNSS Fuel Counter

DOUT Control Via Call

Excessive Idling 

detection

Immobilizer

iButton Read 

Notification

Unplug detection

Towing 

detection

Crash detection

Auto 

Geofence

Manual Geofence

Trip

 

Sleep modes 

GPS Sleep

Online Deep Sleep

Deep 

Sleep

Ultra Deep Sleep

 

Configuration and firmware update 

FOTA Web

FOTA

Teltonika 

Configurator

 (USB, Bluetooth)

FMBT 

mobile application

 (Configuration)

 

SMS 

Configuration, Events, DOUT control, 

Debug 

GPRS commands 

Configuration, DOUT control, Debug 

Time Synchronization 

GPS, NITZ, NTP 

Fuel monitoring 

LLS (Analog), 

LV-CAN200

ALL-CAN300

OBDII dongle, CAN-CONTROL

 

Ignition detection 

Digital Input 1, Accelerometer, External 
Power Voltage, Engine RPM (CAN 
Adapters, OBDII dongle) 

Summary of Contents for FMB122

Page 1: ...Quick Manual v1 6 Dual SIM tracker with external GNSS antenna FMB122...

Page 2: ...he battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic char...

Page 3: ...3 FMB122 Wiki Know your device Figure 1 FMB122 device view...

Page 4: ...0 V DC Digital input channel 3 4 DIN 2 Digital input channel 2 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collector ou...

Page 5: ...5 FMB122 Wiki Figure 3 FMB122 Wiring scheme Wiring scheme 1 Automotive relay 1...

Page 6: ...in Teltonka Configurator Make sure that SIM card cut off corner is pointing outward from slot SIM slot 1 is closer to PCB SIM slot 2 is the top one 3 Connect battery as shown to device Position the b...

Page 7: ...r installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Con...

Page 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Page 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Page 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Page 11: ...Blinking every two seconds Sleep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characterist...

Page 12: ...ut battery 40 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery dischar...

Page 13: ...V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Input Voltage threshold DIN3 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance R...

Page 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 62368 1 standard The device FMB122 is not designed as a navigational device for boats Do not disassemble...

Page 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Page 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Reviews: