Teltonika FMB110 Quick Manual Download Page 9

 

FMB110 | 

Wiki

 

Mounting recommendations 

 

Connecting wires  

 

Wires should be connected while the module is not plugged 
in. 

 

Wires should be fastened to stable wires or other non-
moving parts. Any heat emitting and/or moving objects 
should be kept away from the wires. 

 

There should be no exposed wires. If factory isolation was 
removed while connecting the wires, the isolation material 
should be applied. 

 

If the wires are placed in the exterior or in places where they 
can be damaged or exposed to heat, humidity, dirt, etc., 
additional isolation should be applied and the wires should 
not be loose. 

 

Wires cannot be connected to the board computers or 
control units. 
 

 

Connecting power source 

 

Be sure that after the car computer goes to sleep mode, 
power might be still available on the power wires. 
Depending on the car model, this may happen in 5 to 30 
minutes period. 

 

When the module is connected, measure the voltage again 
to make sure it did not decrease. 

 

It is recommended to connect to the main power cable in 
the fuse box. 

 

3 A, 125 V external fuse shall be used. 
 

 

Connecting ignition wire 

 

Be sure to check if it is a real ignition wire i. e. power does 
not disappear after starting the engine. 

 

Check if this is not an ACC wire (when key is in the first 
position, most of the vehicle electronics are available). 

 

Check if power is still available when you turn off any of 
vehicles devices. 

 

Ignition is connected to the ignition relay output. As 
alternative, any other relay, which has power output when 
ignition is on, may be chosen. 
 

 

Connecting ground wire 

 

Ground wire is connected to the vehicle frame or metal 
parts that are fixed to the frame. 

 

If the wire is fixed with the bolt, the loop must be connected 
to the end of the wire. 

 

For better contact scrub paint from the spot where loop is 
going to be connected. 

 

 

Summary of Contents for FMB110

Page 1: ...Quick Manual v1 0 Advanced tracker FMB110...

Page 2: ...e 6 How to insert Micro SIM card 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Mounting recommendations 9 LED indications 10 Characteristics 10 Basic character...

Page 3: ...3 FMB110 Wiki Know your device Figure 1 FMB110 device view...

Page 4: ...channel 3 4 DIN 2 Digital input channel 2 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Digital output channel 1 Open collector output Max 3 3 A DC 8 DOUT 1 Digital output channel 1...

Page 5: ...5 FMB110 Wiki Figure 3 FMB110 Wiring scheme Wiring scheme 1 Automotive relay 1...

Page 6: ...o SIM card as shown with PIN request disabled or read our Wiki how to enter it later in Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 3 Attach device cover back...

Page 7: ...indow 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Configuration Windo...

Page 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Page 9: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Page 10: ...mode Blinking every two seconds Sleep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic charact...

Page 11: ...ating temperature 25 C to 55 C Storage temperature 40 C to 70 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Features Sensors Accelerometer Scenarios Green Driving Over Spe...

Page 12: ...e V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Analog Input Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 150 k Measurement error on...

Page 13: ...cted Before unmounting the device from the vehicle the 2x6 connector must be disconnected The device is designed to be mounted in a zone of limited access which is inaccessible to the operator All rel...

Page 14: ...your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equipment should not be mixed with general househo...

Reviews: