![Teltonika FM3200 User Manual Download Page 42](http://html1.mh-extra.com/html/teltonika/fm3200/fm3200_user-manual_1084746042.webp)
42
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
0
1
-
Time based acquire interval (ID=11)
Distance based acquire interval
Angle based coordinate acquisition
S8
9.7
IO properties
IO properties
–
are additional data sources which are recorded along with usual GPS data.
IO#1 property parameter (ID=300)
Parameter defines IO property value. Possible values: enabled (value 1), disabled (value 0).
0
1
Disabled Enabled
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
0
byte
-
IO#1 averaging length (ID=305)
S8
IO#1 priority (ID=301)
Parameter defines IO property type of priority: 0 is low, 1
–
high, 2
–
panic, 3
–
security
priority type.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
0
3
0
IO#1 property parameter (ID=300)
IO#1 averaging length (ID=305)
S8
IO#1 High level (ID=302)
Parameter defines high value of triggered IO property. This parameter is used to set thresholds
for IO properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
-2147483648
2147483648
1
IO#1 property parameter (ID=300)
IO#1 averaging length (ID=305)
S32
IO#1 Low level (ID=303)
Parameter defines low value of triggered IO property. This parameter is used to set thresholds
for IO properties to generate events.