3.4.2. SMS/GPRS Command List 

Table 2 Command List 

Command 

Description 

Response 

lvcansetprog # 

Set program number to LV-CAN200/ ALL-CAN300/CAN-CONTROL 
that is connected to FMB1YX. 
# three digit number that identity vehicle. 

Yes 

lvcangetprog 

Get program number from LV-CAN200/ ALL-CAN300 that is 
connected to FMB1YX. 

Yes 

lvcangetinfo 

Get information about connected LV-CAN200/ALL-CAN300. 

Yes 

Lvcanclear # 

Clear Total Mileage (counted), Engine Work Time (counted), Fuel 
Consumed (counted) parameters values.  
# - parameter (0 – Engine work time (counted), 1 – Fuel Consumed 
(counted), 2 – Vehicle Mileage (counted)).  

 

lvcanopenalldoors 

Open [unlock] all doors 

Yes 

lvcanclosealldoors 

Close [lock] all doors 

Yes 

lvcanopentrunk 

Open [unlock] trunk 

Yes 

lvcanturninglights 

One flash of all turn lights ordered trough accidental / blinking turn 
light switch 

Yes 

lvcanwindowsopen:#  open windows xx sec. (one sending of command will cause the 

windows to continue opening for xx seconds). xx: [1,3,5...25,27,29] 

Yes 

lvcanwindowsclose:#  close windows xx sec. (one sending of command will cause the 

windows to continue closing for xx seconds). xx: [1,3,5...25,27,29] 

Yes 

Summary of Contents for CAN-CONTROL

Page 1: ...CAN adapter CAN CONTROL manual v0 1 ...

Page 2: ...er selection 5 3 1 1 CAN CONTROL program number configuration via SMS command 5 3 1 2 CAN CONTROL program number configuration via Configurator 5 3 1 3 Selecting CAN CONTROL program number manually 6 3 2 FMB1YX CAN CONTROL Configuration 7 3 3 FM11YX FMA1YX CAN CONTROL Configuration 7 3 4 SMS Configuration 8 3 4 1 SMS GPRS Commands 8 3 4 2 SMS GPRS Command List 9 3 4 3 FMA1YX FM11YX IO Elements 10 ...

Page 3: ...hicle data Depending on what device CAN CONTROL is used with the connection between CAN Adapter and FM devices can be either via dedicated contacts or USB plug Table 1 CAN CONTROL Technical characteristics Characteristicdescription Value Min Typ Max Unit SupplyVoltage Supply Voltage Recommended Operating Conditions 9 12 16 V CurrentConsumption Working mode with 12V 23 6 mA Sleep mode with 12V 0 95...

Page 4: ... USB Plug to FMA1YX FM11YX device connect CAN CONTROL to other end of the cable Connect Pins 1 8 as specified in wiring scheme Connect car power supply lines to Pin 11 positive Pin 10 Negative For numbered pinout see sticker on CAN adapter Attention Ordered CAN CONTROL packaging may vary standard package for FMB1YX series devices and other package for FMA1YX FM11YX series with Mini USB cable Atten...

Page 5: ...r configuration via SMS command CAN CONTROL program number can be set remotely using SMS command SMS command lvcansetprog X or login pass lvcansetprog X X is new program number value Example lvcansetprog 11434 SMS response LVCAN ProgNum 11434 3 1 2 CAN CONTROL program number configuration via Configurator CAN CONTROL program number can be set via Configurator see Figure 2 Go to CAN Adapter 1 Progr...

Page 6: ...starts blinking and counting second digit of program number To stop counter push SWITCH Release the SWITCH then LED starts blinking and counting third digit on program number To stop counter push SWITCH Release the SWITCH then LED starts blinking and counting fourth digit on program number To stop counter push SWITCH Release the SWITCH then LED starts blinking and counting fifth digit on program n...

Page 7: ...ent The CAN CONTROL I O element can be configured like any other I O element in FMB1YX Configurator When using offline configuration method user can select which CAN data will be read from CAN CONTROL and sent directly to the server without connection to adapter Please note that parameters depend on vehicle manufacturer and vehicle model For further information check CAN CONTROL supported vehicle ...

Page 8: ... configuration can be found in Configurators CAN tab Figure 4 3 4 SMS Configuration All CAN CONTROL IO elements can be configured remotely via SMS command 3 4 1 SMS GPRS Commands1 CAN CONTROL has several dedicated SMS GPRS commands All commands are case sensitive Essential fields in SMS part is Login and Password The login and password are used with every SMS sent to FM device If login and passwor...

Page 9: ...ted Fuel Consumed counted parameters values parameter 0 Engine work time counted 1 Fuel Consumed counted 2 Vehicle Mileage counted lvcanopenalldoors Open unlock all doors Yes lvcanclosealldoors Close lock all doors Yes lvcanopentrunk Open unlock trunk Yes lvcanturninglights One flash of all turn lights ordered trough accidental blinking turn light switch Yes lvcanwindowsopen open windows xx sec on...

Page 10: ... position 2010 2014 Total fuel used 2020 2023 Fuel level liters 2030 2034 Engine RPM 2040 2044 Total mileage 2050 2053 Fuel level percent 2060 2064 Program number 2070 2073 Module ID 2080 2083 Total Mileage counted 2110 2113 Fuel Consumed counted 2120 2123 Engine Temperature 2170 2174 Control State Flags 2230 2233 Security State Flags 2320 2323 Table 4 CAN CONTROL IO parameters configuration Param...

Page 11: ...panic 3 4 4 5 1st LVCAN property parameter operand ID 45101 Minimum Value Maximum Value Default Value Goeswith dependson parameters Value Type 0 2 0 Send data with 0 if ignition is off ID 45001 Program Number ID 45002 Uint8 Minimum Value Maximum Value Default Value Goeswith dependson parameters Value Type 0 1 0 LVCAN Mode ID 45000 Program Number ID 45002 Uint8 Minimum Value Maximum Value Default V...

Page 12: ... property parameter High level ID 45102 1st LVCAN property parameter Low level ID 45103 1st LVCAN property parameter Event only ID 45104 1st LVCAN property parameter averaging constant ID 45105 1st LVCAN property parameters Send SMS to ID 7141 1st LVCAN property parameters SMS Text ID 8141 Uint8 Minimum Value Maximum Value Default Value Goeswith dependson parameters Value Type 0 255 0 1st LVCAN pr...

Page 13: ...ty parameter priority ID 45100 1st LVCAN property parameter operand ID 45101 1st LVCAN property parameter High level ID 45102 1st LVCAN property parameter Event only ID 45104 1st LVCAN property parameter averaging constant ID 45105 1st LVCAN property parameters Send SMS to ID 7141 1st LVCAN property parameters SMS Text ID 8141 Uint8 Minimum Value Maximum Value Default Value Goeswith dependson para...

Page 14: ... LVCAN property parameter operand ID 45101 1st LVCAN property parameter High level ID 45102 1st LVCAN property parameter Low level ID 45103 1st LVCAN property parameter Event only ID 45104 1st LVCAN property parameters Send SMS to ID 7141 1st LVCAN property parameters SMS Text ID 8141 Uint16 Minimum Value Maximum Value Default Value Goeswith dependson parameters Value Type 0 10 0 1st LVCAN propert...

Page 15: ...e counted 45220 45221 45222 45223 45224 7153 8153 Fuel Consumed counted 45230 45231 45232 45233 45234 7154 8154 Engine Temperature 45280 45281 45282 45283 45284 45285 7159 8159 Control State Flags 45340 45341 45342 45343 45344 7165 8165 Security State Flags 45430 45431 45432 45433 45434 7174 8174 Battery Voltage 45720 45721 45722 45723 45724 7203 8203 CNG Used 45900 45901 45902 45903 45904 7237 82...

Page 16: ... 33 4 87 meters 1 Total Mileage counted 34 4 105 meters 1 Fuel Consumed 35 4 83 Ltr 10 0 1 Fuel Consumed counted 36 4 107 Ltr 10 0 1 Fuel Level 37 1 89 1 Fuel Level liters 38 2 84 Ltrs 10 0 1 Engine RPM 42 2 85 1 Engine Temperature 44 1 115 C x 10 0 1 signed Accelerator Pedal Position 45 1 82 1 Vehicle Speed 46 1 81 km h 1 Control State Flags 52 4 123 Security State Flags 61 8 132 Battery Level pe...

Reviews: