IPDP - installation and operating instructions
26
3.2.3 Time Parameters
After making changes use the save changes button.
1 – max. time, for which the DoorPhone is hanging up, this time can be
extended during call by sign choice from telephone (* or #) – see page 23.
2 – Number of incoming call rings, the DoorPhone pick up after preseted
number of rings. After detection first ring – LED on front panel blinking. The
number can be set from 1 to 9.
3 – max. time [sec] among button presses [range 1-9]
normal buttons
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
-
dialing – if the button, we are pressing, is the first password number
for switch closing, so the choice is delayed by this w time.
keyboard
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
dialing the same as of phone, if time after the last pressed button
is bigger than w time, then the dialing starts. If the number is
incomplete, it is necessary to hang up (X button) and the
dialing will be repeated.
dialing from memory, if time following the first pressed button is
longer than w time, then the entry of memory number has to
be repeated.
4 – time [sec] for which the guard will hang up, before repeated dialing (button
pressing during call or dialing, busy tone detection) [range 1-5]
5 – after finishing the dialing it calculates time (ringing tones). If the number
exceeds time in second, it will hang up [range 10-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
6 – In default is status of DoorPhone signalling acoustically. If signalling makes
problem, so this signalling pick up / hang up prohibited.