background image

• 

*33 (*DD) 

 

Show Selection

 -  Some dual hybrid interface units can be operated in a dual studio 

mode, where the two hybrids are used independently in two studios. In these cases 
Desktop Directors may choose from "

Show 1

" (hybrid 1) or "

Show 2

" (hybrid 2). If 

your system is configured for one of the dual modes you can use the following 
shortcuts to change the 

Show 

being controlled by a specific Call Controller: 

• 

*74691 (*SHOW1) 

• 

*74692 (*SHOW2) 

NOTE: When the Call Controller is used with the Series 2101 it cannot choose a 
show. However, a Desktop Director can be used to select the show being used on 
that 2101 Studio Interface, and all Call Controllers, Console Directors and Desktop 
Directors connected to that Studio Interface will, of course, be associated with that 
show as well. 

3 Connections 

Connecting the Call Controller to your Telos Talkshow system is identical to connecting 
a Desktop Director, as covered in your Telos Talkshow system manual. This jack is 
labeled 

Telos Interface

 and the connection is made using an 8- pin miniature modular 

cable (RJ- 45 style) provided with the unit. An LED adjacent to this jack will illuminate 
continuously if the connection is correct. 

In cases where two Telos control units share the same Desktop Director port on the 
Talkshow system, one unit will need to have its termination resistors disabled (units are 
shipped with the terminators enabled). To do so, remove the unit's cover by removing 
the screws around the edge of the black metal cover. Inside locate two 3- pin headers, 
labeled "JP- 1" and "JP- 2" and move the jumper blocks top the alternate positions for 
both jumpers. Replace the cover and screws. 

The connection to the telephone set is made using a standard 6- position 2- pin 
miniature modular cable (RJ- 11 style) to the jack on the unit labeled 

Telephone Set

. The 

center two pins are used. If your Telephone does not use this type of connector an 
adaptor may be purchased locally. 

4  Telephone Set Interface 

Most analog telephone sets intended for use with standard analog "POTS" line will work 
with the Call Controller for basic operation. The "Telephone Set" jack provides a signal 
that emulates a USA analog telephone line as follows (for more detailed information see 
TIA/EIA- 464- B): 

 

Loop Specifications: 

Loop Current - 25 mA 

 

 

Loop Voltage - 48 VDC 

Ringer Specifications:

 

Configuration  -  Metallic (line to line) 

 

 

Voltage/Frequency - 20 Hz/ 51 Volts RMS (Sine) 

 

 

Max Ringer Equivalence - 2 REN 