Appendix E:  Viewing, Saving, and Converting Received Data on Your PC 

 
The TSUR-400 Uplink Receiver exports messages over its Mini-DIN connector.  The uplink receiver 
automatically exports each new message when it is received and manually exports 1-99 stored 
messages if you use the “Msg Export” feature.  To store these messages on your PC, you will need to 
use a TSC-5A USB Cable or a serial data transfer cable (WI007325-001) to connect your PC to the 
Mini-DIN connector on your TSUR-400. 
 
The TSC-5A USB cable is typically used with Telonics Data Converter (TDC) to view, save, and 
convert messages on your PC.  TDC contains a proprietary driver for the TSC-5A requiring no further 
driver installation as long as the TSC-5A is used with TDC. If, however, you wish to use the TSC-5A 
with programs other than TDC (e.g. HyperTerminal or other terminal emulation programs) to capture 
data from the TSUR-400, you may install the TSC-5A Virtual COM Port Driver, which will enable 
TSC-5A use with those programs.  TDC and the Virtual COM Port Driver are available for download 
from the Telonics website. 
 
The serial data transfer cable (WI007325-001) that Telonics previously sold will also allow you to 
connect a TSUR-400 uplink receiver to your PC.  If your PC doesn’t have an available COM port, you 
will need to purchase a USB-to-Serial adapter or switch to a new TSC-5A USB cable.  The serial data 
transfer cable also works with Telonics Data Converter and terminal programs. 
 
 

Using Telonics Data Converter (TDC) 

 
TDC is available for download on the Telonics website and will save TSUR-400 messages to a text file 
free of charge.  You will have to purchase an authorization code if you want TDC to convert uplink 
messages. 
 
 

Using HyperTerminal or Other Terminal Applications 

 
HyperTerminal is typically installed and available as part of WindowsXP.  The instructions below 
describe how to configure and use HyperTerminal on Windows XP.  The TSUR-400 Uplink Receiver 
will work with many other terminal programs that can be downloaded or purchased online.  You may 
need to follow similar configuration steps if use another terminal program or operating system. 

 
START MENU – PROGRAMS – ACCESSORIES – COMMUNICATIONS- 

and select 

HYPERTERMINAL. 

Other terminal programs can be used for this application if the user has a 

preference for a specific alternative.   
 
Click on 

HYPERTERMINAL

 to start the program and proceed to configure the terminal program for 

the TSUR-400 uplink receiver by using the following sequence of steps. 
 
Step 1

. Connection Description 

Dialogue Box

 … New Connection:

  Provide a 

Name

 for the 

configuration  i.e. TSUR-400.  Next select and assign an appropriate 

ICON

. Select 

OK

 

 
Step 2.  

Connect To:

  Dialogue Box: The first three option fields (

Country/Region, Area Code, 

Phone number

) are not used for the TSUR-400 and can remain as defaults. The fourth option field 

Connect using: 

This field should be filled in by picking the correct COM port on your computer -- the 

COM port that you have selected to attach the serial data transfer cable and TSUR-400.  Finding the 

Summary of Contents for TSUR-400

Page 1: ...E MAIL info telonics com www telonics com TSUR 400 RECEIVER MONITOR OPERATION and PROGRAMMING MANUAL PB007326 Rev E 2012 08 07 Copyright Notice Copyright 2012 Telonics Inc All Rights Reserved No part...

Page 2: ...xport 9 J Msg Delete 10 K Setup 10 Setup Menu Level 2 Screen 11 A 28bit Id Tbl 11 B Edit Id Fltr 12 C Split Setup 13 D Beep Tone 13 E Lite On Time 13 F Set Time 14 G Set Date 14 H Sw Closure 14 I Sque...

Page 3: ...d toggle menu items On or Off The FN key is also used to exit from the Message screen or to enter the Menu system DN P1 Key The DN key is a scroll down key used for scroll down menu options The DN key...

Page 4: ...een which displays the current date and time number of stored messages selected group or all ID codes data bytes split or decimal and diagnostics dg on or off Changes or modifications to these paramet...

Page 5: ...automatically whenever a new message is received or manually by pressing the DN key at the Main screen The information displayed is the date and time of the most recent message current message number...

Page 6: ...t a time with the most recent message displayed first The scroll speed increases when the UP or Dn key is depressed for more than 2 seconds When the last message is scrolled a message indicating end o...

Page 7: ...haracter on white background with a black block Pressing the FN key allows the selected function to be modified Exiting back to the Main Screen is accomplished by selecting EXIT using the UP or DN key...

Page 8: ...RF Pwr mode before directly connecting it to a transmitter You may damage the TSUR 400 if you directly connect a transmitter while it is in receive mode 4 Comparison of the number of data groups the...

Page 9: ...is Off All is displayed on the left side of the bottom line of the display When Id Fltr is On the receiver will display information only when a new message is received for an ID that is in the GRouP o...

Page 10: ...sed to begin the process Press the FN key to return to the Main Screen When exporting messages the following parameters define how the information is sent RS 232 9600 Baud 8 Bits No Parity 1 Stop Bit...

Page 11: ...enu screen Line 1 Exit Line 2 28bit Id Tbl Line 3 Edit Id Fltr Line 4 Split setup Beep Tone Lite On Time Set Time Set Date SW Closure Squelch Fact Default RF Pwr Dsply PC connect A 28bit Id Tbl The 28...

Page 12: ...coming messages or just selected messages maximum of 9 Edit Id Fltr is selected by highlighting the feature and pressing the FN key The following display appears Choices are Exit Erase All or Edit or...

Page 13: ...rated when a beep occurs When this feature is selected and the FN key pressed the following appears Choices are 1 to 9 with each number corresponding to a different tone Each time a new number is sele...

Page 14: ...ction mm Selection between 01 and 12 is accomplished using the UP DN keys When the correct number is displayed the FN key advances the highlight to the day selection dd Selection between 01 and 31 is...

Page 15: ...t J Fact Default Warning Implementing this function will erase ID codes the user may have programmed into the TSUR 400 This feature is used to return the unit to the factory defaults that were origina...

Page 16: ...e reading programming of user parameters and reading clearing of stored messages Note When the receiver is in this mode the RF section is disabled precluding reception of messages When this feature is...

Page 17: ...fff fff ddd ddd eee CR where LF ASCII Line Feed code 0x0A y year decimal 2001 2002 etc M month decimal 1 12 d day of month decimal 1 31 h hour decimal 0 23 m minute decimal 0 59 s second decimal 0 59...

Page 18: ...0 FF eeee error messages Alpha letters CR ASCII Carriage Return code 0x0D d Diagnostics Mode with Split Bits COMMA delimited field information as follows LF yyyy MM dd hh mm ss iiiiii fff fff CCC pp p...

Page 19: ...l message received was longer or shorter than the message length indicated by the three bit message length indicator which was transmitted b Length Parity Error Indicates that the three bit message le...

Page 20: ...External Power 9 to 48 Vdc with power adapter pack Power Measurement 0 01 to 1 watt 0 to 30 dBm For measuring power levels exceeding 1 0 watt 30 dBm appropriate external attenuators are required NOTE...

Page 21: ...ORANGE and will remain ORANGE for two to three minutes until the charger brings the battery to the correct voltage level It will then turn RED to indicate that the charger is in the rapid charge state...

Page 22: ...gin Msg Delete None UP DN Select FN Accepts Exit 28Bit ID Tbl Edit ID Filt Split setup Beep Tone Lite On Time Set Time Set Date Sw Closure Squelch Fact Default RF Pwr Dsply PC Connect Bit Splt 001 00...

Page 23: ...orks with Telonics Data Converter and terminal programs Using Telonics Data Converter TDC TDC is available for download on the Telonics website and will save TSUR 400 messages to a text file free of c...

Page 24: ...n STOP and data collection to the text file will be terminated TSUR 400 WARRANTY Telonics warrants the TSUR 400 to be free from defects in material and workmanship for 90 days from the date acquired T...