Mounting instructions for TQ12 ver 2 Production tracker

 
 

- Installation for collecting positioning and production data 

This scenario should be used when the unit shall collect the machine's running and production hours, and alarms. When the main switch is 
turned off the unit has limited possibility to send data. The unit is equipped with a back-up battery, fully charged and in good condition it 
can send positions for some hours after the main power switch is turned off. In this scenario, the unit draws no power from the battery 
when the main power switch is turned off. 
 

Red

 wire connects to b at a suitable location, after the main switch. Use a 2 or 3 A fuse to protect the unit. The power must be 

constant when machine is running 

Black

 wire is connected to ground. 

Yellow

 wire is connected to the signal when the engine is turned on, such as the ignition. The signal should be 7.5-30 VDC. 

Optional, 

White/Green

 wire is connected to the signal that is high when the machine produces. The signal should be 2.5-30 VDC. 

Optional, 

White

 wire is connected to the alarm (2.5-30 VDC). 

The other wires are used for TelliQ accessories. 

 

 

 

 

Page ​ 

6 (8)

 

 

Summary of Contents for TQ12 ver 2

Page 1: ...ahamsson 2018 04 24 TQ 18 196 2 Production tracker Reviewed by Joel Verpers TQ12 ver 2 Production tracker Mounting instruction Contact TelliQ Customer Center after each installation for function contr...

Page 2: ...he following scenarios Main power switch on negative side main power switch is located on the machine negative side o Installation for collecting positioning and production data running hours etc Main...

Page 3: ...or some hours after the main power switch is turned off In this scenario the unit draws no power from the battery when the main power switch is turned off Red wire connects to battery at a suitable lo...

Page 4: ...led as described below without relay running and production hours will be counted when the main switch is off and provide incorrect data in the TelliQ system and increase the power consumption of the...

Page 5: ...ion after the main switch has been turned off Red wire connects to battery at a suitable location before the main switch Use a 2 or 3 A fuse to protect the unit The power must be constant when machine...

Page 6: ...off In this scenario the unit draws no power from the battery when the main power switch is turned off Red wire connects to battery at a suitable location after the main switch Use a 2 or 3 A fuse to...

Page 7: ...is in deep sleep mode Off Causes GNSS module is short circuited Unit is powerless Device is not working or Unit firmware is being flashed It can take up to 5 minutes before the unit has a connection...

Page 8: ...ORANGE DOUT1 N A in standard application VIOLET DOUT2 N A in standard application GREEN 1WIRE DATA N A in standard application BLUE 1WIRE POWER N A in standard application GSM Quad band module with in...

Reviews: