background image

Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W 

 
2-2-2 Accumulated Power Consumption (KW/h) 

When receiving Meter Get Command, it will report Meter Report Command to 

the node. 
 

Meter Get Command:   
[Command Class Meter, Meter Get, Scale = 0x00 KW/h)]

 

         

Meter Report Command: 
[Command Class Meter

Meter Report

Rate Type = 0x01

  Meter Type = 

0x01

  Precision = 2

Scale = 0x00

Size = 4

Meter Value (KWh)] 

 
          Example: 
          Scale = 0x00 (KWh) 
          Precision = 2 
          Size = 4 Bytes (KW/h) 
          Meter Value 1 = 0x00(KWh) 
          Meter Value 2 = 0x01(KWh) 
          Meter Value 3 = 0x38(KWh) 
          Meter Value 4 = 0xA3(KWh) 
 
          Accumulated  power  consumption  (KW/h)  =  (Meter  Value  2*65536)  +  (Meter 

Value 3*256) + (Meter Value 4) = 800.35 (KW/h) 

 
2-2-3 Clearing accumulated power consumption 
      Whenever  re-start  counting  the  accumulated  power  consumption  is  needed,  you 

can use Meter Reset Command to clear it. 

 

Meter Reset Command: [Command Class Meter, Meter Reset]

 

 
2-2-4 AC load Voltage (V) 
        When receiving Meter Get Command, it will report Meter Report Command to the 

node. 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] 

   

Meter Report Command: 
[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 

0x01

Precision = 1

Scale = 0x04

Size = 2

  Meter Value(V)] 

 
Example: 
Scale = 0x04 (V) 
Precision = 1   
Size = 2 (2 Bytes of    V) 
Meter Value 1 =    0x09(V) 
Meter Value 2 =    0x01(V) 
AC load Voltage =    (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) 
 
2-2-5 AC load current ( I ) 
        When receiving Meter Get Command, it will report Meter Report Command to the 
node.

 

 

Meter Get Command:   
[Command Class Meter, Meter Get, Scale =0x05(I)]
 

 

Meter Report Command: 
[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 0x01

Precision = 2

Scale = 0x05

Size = 2

Meter Value(I)] 

 
Example: 
Scale = 0x05 (I) 
Precision = 2   
Size = 2 (2 Bytes of I) 
Meter Value 1 =    0x01(I) 
Meter Value 2 =    0x21(I) 
AC load current =    (Meter Value 1*256) +(Meter Value 2)= 2.89 (A) 
 
2-2-6 load power factor (PF) 
        When receiving Meter Get Command, it will report Meter Report Command to the 
node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] 

 

Summary of Contents for PAN11-1B

Page 1: ...lashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be e...

Page 2: ...the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do no...

Page 3: ...ommand Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consu...

Page 4: ...ge V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report...

Page 5: ...eport its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold...

Page 6: ...On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update o...

Page 7: ...sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11 5B Specifications are subject to change and improvement w...

Page 8: ...ng antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...

Reviews: