background image

 

3

1  Basic functions of the GM-900 modem 

  Remote management of GSM Pager2, GSM  Pager3, GSM  Pager3 Z6, GSM Gate 

Control, GSM/GPRS ProCom, GSM/GPRS easyAID devices as well as GSM 
Ultimate alarm control panel manufactured by T.E.L.L. Ltd., using GSM data call 
(CSD service). 

  Remote management of Paradox, DSC, Crow etc. alarm control panels connected 

to GSM Adapter 

Mini

, GSM Line Pro5 or GPRS Adapter communicator, using 

BELL 103/v.21 communication on GSM data call. 

2  Software applied during the use of the modem 

  Remoter programs applicable for devices manufactured by T.E.L.L. 

  VirtualModem.exe (on CD enclosed) 

  Programming software recommended for Paradox, DSC, etc. Alarm control panels 

(Espload, WinLoad, BabyWare, DLS, etc.) 

3 Software installation 

The drivers and software necessary for the use of the modem can be installed from the 
included CD. The installation starts immediately when inserting the CD. Select the 
GSM-900 Modem option in the installation wizard. In case that for some reason the 
installation does not start automatically, run 

setup.exe

 application from the CD. 

The VirtualPort driver to be installed by setup.exe 

runs on

 

32 and 64-bit Windows XP 

and Windows 7

 operating systems. 

4  Putting the modem into operation 

  To establish the GSM data communication it is necessary both in the GM-900 

modem and in the device wished to program the use of SIM cards on which the 
GSM data call (CSD service) is enabled.  

  Disable PIN code request on the SIM card, then push it into the modem until it 

clicks, as shown in the figure below: 

Removing the SIM card: push the overhanging part of the SIM card towards the 
modem until it clicks, then release and pull out the card from the slot. 

  Connect the enclosed GSM antenna to the modem. 

Summary of Contents for S900 B09

Page 1: ... 05 09 2012 Features USB interface GSM data transfer GPRS data transfer BELL 103 v 21 communication Applications Remote programming of T E L L devices Remote programming of Paradox DSC Crow etc alarm control panels adapted to GSM network with GSM Adapter Mini GSM Line Pro5 or GPRS Adapter communicator ...

Page 2: ...s for remote programming 5 5 6 Troubleshooting 6 5 6 1 Setting the Espload program 6 5 6 2 Setting the WinLoad program 7 1 Basic functions of the GM 900 modem 3 2 Software applied during the use of the modem 3 3 Software installation 3 4 Putting the modem into operation 3 5 BELL 103 remote programming using GSM data transfer 4 6 Remote programming of T E L L devices 8 7 LED signals 11 8 Technical ...

Page 3: ...ecessary for the use of the modem can be installed from the included CD The installation starts immediately when inserting the CD Select the GSM 900 Modem option in the installation wizard In case that for some reason the installation does not start automatically run setup exe application from the CD The VirtualPort driver to be installed by setup exe runs on 32 and 64 bit Windows XP and Windows 7...

Page 4: ...necessary for the GSM Line Pro5 module In the v1 03 BELL version of the GSM Line Pro5 programming software in the Set module parameters Edit parameters window a Bell 103 tab can be found On this site it can be enabled to accept all incoming data calls for programming or only the ones coming from the specified phone numbers If callback option is set in the alarm control panel then here should be sp...

Page 5: ...d For this the Bosch V21 and DS7400 options were added In case of trying to program an alarm panel of this sort and are encountering connection problems permanently then select the corresponding BELL103 mode Bosch V21 or DS7400 Start the programming software of the alarm control panel e g Espload Select the created virtual serial port for modem serial port at the modem settings section in the alar...

Page 6: ...in the GSM Line Pro5 GSM Adapter Mini or GPRS Adapter module supports GSM data call service CSD ask the GSM service provider If you wish to use a virtual port application from a different manufacturer on the PC and problems are detected during its operation then the virtual port installed by VirtualModem exe may be removed using VSRemove exe program If errors occur frequently during data communica...

Page 7: ...7 5 6 2 Setting the WinLoad program Example for WinLoad program configuration ...

Page 8: ...is expressly necessary only for remote programming over BELL103 of alarm control panels connected to line adapter modules 2 Open the remoter program recommended for the specific device 3 Select the serial port where the GM 900 or GT64 modem is connected For GSM Ultimate and GSM Pager2 Example For GSM Pager3 For GSM Gate Control ...

Page 9: ...access code of the device you wish to program Example For GSM Pager3 Code must be entered before connecting For GSM Ultimate and GSM Pager2 For GSM Gate Control Code must be entered while connecting The window appears after connection has established and the code must be entered at that moment ...

Page 10: ... case of GSM Gate Control connection progress is shown by the program step by step automatically 6 After the connection has established all the functions of the remoter program can be accessed used the same way as the remote device would be connected to the PC through physical serial port 7 When you finished programming the communication can be terminated by closing the connection Example For GSM ...

Page 11: ...al specification Supply voltage 5V DC Nominal current consumption 30mA Maximum current consumption 500mA Operating temperature 10ºC 60ºC Transmission frequency GSM 900MHz 1800MHz and GSM 850MHz 1900MHz Dimensions 77x37x21 mm Net weight 70g Gross weight packed 165g 9 Package contents GM 900 modem with USB cable GSM 900MHz 1800MHz antenna CD application manual warranty card ...