2.
WIRING OF THE MODULE:
Module versions:
The
Pager4
can be mounted with European
2G, 3G, 4G
or international
3GA
and
4GA
phones, and can be ordered in
IN4.R2
and
IN6.R1
version
based on the number of inputs, and in
Basic
or
PRO
version based on the
functionality.
Inputs:
The
NO
and
NC
contacts are defi ned between the
COM
terminal and the
given input. The type of an input can be selected in the programming
software.
Outputs:
The output provides normally open
(NO)
, dry (potential free) contact
by default and closed contact upon control. The highest load support-
ed by the relay is
1A.
Attention! Do NOT connect the module’s terminals directly or indi-
rectly to the protective ground because this may damage the module!
Pager4 IN4.R2 wiring example:
V+ V- IN1 IN2 IN3 IN4
OUT1
OUT2
NO
NO
NC
NC
NO
NO
Control Control
+
-
12-30 AC/DC