Telkom Telmor WWK-9103 User Manual Download Page 5

GZT TELKOM-TELMOR Sp. z o.o., ul. Schuberta 104, 80-172 Gdańsk, Poland 
T: +48(58) 3823 349, e-mail: export@telmor.pl, www.telmor.pl 

 
 

 

 
 
 

4.

 

Programming

 

The device is programmed using the display and a 5-button keypad. The programming procedure for individual parameters is given below. 

 

 
 

During the powering up: 

 

the programming mode is on standby: 

 

if no changes are made in the programming, the system is configured as follows: 

o

 

UHF1 -> 0  UHF filters  

o

 

UHF2 -> 0  UHF filters 

o

 

UHF3 ->10 UHF filters 

 

all UHF filters are deactivated (the display shows “off”), 

 

dampers are in zero position. 

 

 
 

     4.1  Return to default settings  

 

If it is necessary to return to default settings: 
      1. Unplug the power cable 
      2. Press esc and keep it depressed 
      3. Plug the power cable 
 
      All programming parameters are deleted and the display shows the message “Default Settings.” 
                                                                                    
  

                                                                                  

 

 

    

 

 

      4. Release the esc button 

  
 
 

 

 

Confirm the value (

V

browse menu functions, 

increase the displayed value "+" 

- browse the menu, 

- decrease the displayed value "-" 

Return to the previous menu (

^

Summary of Contents for WWK-9103

Page 1: ...GZT TELKOM TELMOR Sp z o o ul Schuberta 104 80 172 Gda sk Poland T 48 58 3823 349 e mail export telmor pl www telmor pl WWK 9103 Programmable Multiband Amplifier User Manual IO 7538 355 01...

Page 2: ...Recycling of waste electric and electronic equipment This symbol on the product or its package indicates that the product is subject to Directive 2002 96 EC WEEE and shall not be disposed of together...

Page 3: ...l may be expanded from 8 up to 56 MHZ 1 up to 7 TV channels UHF1 UHF3 inputs enable to supply preamplifiers with 12 V or 24 V voltage 5 inputs FM VHF UHF1 UHF2 UHF3 UHF amplification 55 dB VHF amplifi...

Page 4: ...ed area The natural ventilation shall be provided by ventilation openings Leave a minimum 15 cm space around the device to ensure maximum ventilation During the installation of control unit or works o...

Page 5: ...gured as follows o UHF1 0 UHF filters o UHF2 0 UHF filters o UHF3 10 UHF filters all UHF filters are deactivated the display shows off dampers are in zero position 4 1 Return to default settings If it...

Page 6: ...In brief Use to navigate the menu Press enter to enter the menu Press esc to exit the menu press menu to return directly to the configuration menu Note After a minute of inactivity the control unit wi...

Page 7: ...GZT TELKOM TELMOR Sp z o o ul Schuberta 104 80 172 Gda sk Poland T 48 58 3823 349 e mail export telmor pl www telmor pl 6 Operation diagram...

Page 8: ...GZT TELKOM TELMOR Sp z o o ul Schuberta 104 80 172 Gda sk Poland T 48 58 3823 349 e mail export telmor pl www telmor pl 7 Block diagram...

Page 9: ...ntrol dB 0 to 20 UHF gain control dB 0 to 20 VHF UHF max output level IM3 60dB dB V 120 117 Filters arrangement 3 1 3 1 5 7 8 2 2 2 7 9 10 Width of filtering channels MHz 8 to 56 Filter selectivity up...

Reviews: