ME310G1 Hardware Design Guide
1VV0301588 Rev. 16
Page 41 of 95
2021-10-27
Not Subject to NDA
Note: Consider the voltage drop under max current conditions when
defining the voltage detector threshold to avoid unwanted shutdown.
5.6.2
Fast Shut Down by Software
The Fast Shut Down can be triggered by AT command.
5.7
Communication Ports
5.7.1
USB 2.0 HS
The Telit ME310G1 module includes an integrated universal serial bus (USB 2.0 HS)
transceiver. The following table lists the available signals:
PAD
Signal
I/O
Function
NOTE
U19
USB_D+
I/O
USB differential Data (+)
V18
USB_D-
I/O
USB differential Data (-)
T18
VUSB
AI
Power sense for the internal USB transceiver.
Table 25: USB 2.0HS available signals
The following are the USB_VBUS input voltage range and input current:
Table 26: Voltage range
Table 27: Input current
Parameter
Min
Max
ABSOLUTE MAXIMUM RATINGS
–
NOT FUNCTIONAL
USB_VBUS Input level
-0.3V
6.0V
Operating Range
USB_VBUS Input high level
1.0V
5.25V
USB_VBUS Input low level
0V
0.4V
Parameter
TYP
Current characteristics:
USB_VBUS Input Current
6uA