2.2 Weight
GE864
: 6 gr
GC864
: 8 gr. (preliminary)
2.3 Environmental requirements
The
Telit GE864
and
GC864
modules are compliant with the applicable ETSI reference
documentation GSM 05.05 Release1998.
2.3.1 Temperature range
GE864-QUAD
/
GE864-PY
GC864-QUAD /
GC864-PY
Temperature in normal operating conditions
–10°C
÷
+55°C
–10°C
÷
+55°C
Temperature in extreme operating conditions*
–30°C
÷
+80°C
(preliminary)
–30°C
÷
+80°C
(preliminary)
Temperature in storage conditions
–30°C
÷
+85°C
–30°C
÷
+85°C
*
Temperature exceeding the range of normal operating conditions can affect the sensitivity, the performance and
the MTBF of the module.
2.3.2 Vibration Test (non functional)
•
10
÷
12Hz ASD = 1.92m 2 /s 3
•
12
÷
150Hz –3dB/oct
2.3.3 RoHS compliance
As a part of Telit corporate policy regarding environmental protection, the
GE864
and
GC864
comply
with the RoHS (Restriction of Hazardous Substances) directive of the European Union.(EU
Directive 2002/95/EG).
2.4 Operating Frequency
The operating frequencies in GSM, DCS, PCS modes are conform to the GSM specifications.
Mode
Freq. TX (MHz)
Freq. RX (MHz)
Channels (ARFC) TX - RX offset
850
824.2÷848.8
869.2÷893.8
0 ÷ 124
45 MHz
890.0 - 914.8
935.0 - 959.8
0 – 124
45 MHz
E-GSM-900
880.2 - 889.8
925.2 - 934.8
975 - 1023
45 MHz
DCS-1800
1710.2 - 1784.8
1805.2 - 1879.8 512 – 885
95 MHz
PCS-1900
1850.2 - 1909.8
1930.2 - 1989.8 512 - 810
80 MHz