The LCP-32/16 can usually be connected to a KP-32 and used without any additional intervention. Up to three LCP-32/16
panels can be connected. They are assigned in order of their connection. The first LCP32/16 that is connected to a KP-32
is assigned (by default) to keys 1-16. The second LCP-32/16 is connected to the first LCP-32/16 and is assigned (by
default) to keys 17-32. The third LCP-32/16 is connected to the second LCP-32/16 and is assigned (by default) to keys 33-
48. The only time that the KP-32 will need to be configured for use with an LCP-32/16 is when the KP-32’s LCP-32/16
settings have been changed from their defaults, or when you need to change the settings from their defaults such as when
an LCP-32/16 is only needed on keys 17-32.
To change the LCP-32/16 configuration on the KP-32 do the following:
1. Press the
MENU
key.
2.
Display
will appear in the Call Waiting Window (CWW).
3. Press the
↓↓
↓↓
↓↓
↓↓
↓↓
key until
Service
appears in the CWW.
4. Press the
PGM
key.
5.
Aux Inputs
will appear in the CWW.
6. Press the
↓↓
↓↓
↓↓
↓↓
↓↓
key until
LCP-32
appears in the CWW.
7. Press the
PGM
key.
8.
1-16: Yes
or
1-16: Skip
will appear in the CWW.
9. You can enable (
Yes
) or disable (
Skip
) the LCP-32/16 key assignments by using the
FWD
key.
10. Press the
↓↓
↓↓
↓↓
↓↓
↓↓
key again and
17-32: Yes
or
17-32: Skip
will appear in the CWW window.
11. You can enable (
Yes
) or disable (
Skip
) the LCP-32/16 key assignments by using the
FWD
key.
12. Press the
↓↓
↓↓
↓↓
↓↓
↓↓
key again and
33-48: Yes
or
33-48: Skip
will appear in the CWW window.
13. You can enable (
Yes
) or disable (
Skip
) the LCP-32/16 key assignments by using the
FWD
key.
14. Pressing the
↓↓
↓↓
↓↓
↓↓
↓↓
key will take you back to the display in step 8.
15. Press the