6.4.2
Minimum attenuation requirements (linearize between points)
Frequency (Hz)
Active (dB)
Upper limit
200
2
300
-1
400
-2
600
-3
800
-1
1000
0
6.4.3
ANR test procedure
Required equipment
The Airman 850 ANR test and adjustment procedure requires the following acoustic test
equipment and custom fixture:
–
Audio Test System (Audio Precision or equivalent test system) or
–
Artificial Mouth (Bruel & Kjaer 4227) or equivalent speaker
–
Artificial Ear with 6cc Coupler (Bruel & Kjaer 4153)
–
Supporting hardware for Microphone
–
Supporting hardware and software for audio test system
–
Custom ANR test and adjust fixture
Test setup block diagram
Figure 6.5:
Test setup block diagram