![TELEWAVE 44L1 Operation Manual Download Page 12](http://html1.mh-extra.com/html/telewave/44l1/44l1_operation-manual_1083007012.webp)
Telewave, Inc.
Model 44L1/L1P
Page 11
VSWR Calculation
5.05
The following procedure will assist the user in determining the
Voltage Standing Wave Ratio.
Step
Procedure
1
Perform the procedures outlined in 5.03 and 5.04. Record the
true incident and reflected power.
2.
Refer to the VSWR Chart on the rear of the instrument or Figure
7-1. Apply the readings from Step 1 to the chart.
3.
The VSWR is read from the nearest sloping line. For higher
accuracy, calculate the VSWR by the formula:
True Power at Load Calculations
5.06
The following procedure will assist the user in determining the
actual power delivered to the load.
Step
Procedure
1
Perform the procedures outlined in 5.03 and 5.04. Record the
true incident and reflected power.
2
Subtract the reflected power from the incident power.
This difference is the true power at the load.
VSWR =
1 +
P
REV
(Watts)
P
FWD
(Watts)
1 -
P
REV
(Watts)
P
FWD
(Watts)