TeleVue GIBRALTAR HD4 Instructions Download Page 2

32 Elkay Dr., Chester, New York  10918  (845) 469-4551  

televue.com

Tele Vue

V i s i o n a r y

®

• 

T

ele Vue’s 4” scopes. Because the cradle on the Gibraltar HD5 is deeper than on the 

HD4, a 4” scope must be raised in the cradle for proper altitude balance. The scope is 

properly balanced in altitude when the center of the tube lines up with the Gibraltar HD 

sticker on the vertical axis. If your scope uses our 4” Mount Ring Set MRS-4011, attach 

its bottom-plate on the top of the mount cradle using the four ¼-20 button head screws 

supplied. If using our 4” clamshell-style ring, employ our Mounting Adapters BPL-1098 or 

AVT-1011 between the clamshell and mount cradle to raise the scope. This last configura

-

tion requires 1½” studs or similar ¼”-20 hardware (not supplied) to pass through the mount 

cradle, mounting adapter plates, and thread into the clamshell.

• Mounting other Tele Vue Telescopes. If you have MRS-5000 rings, leave the base plate, without rings, attached to 

the cradle. Thread the supplied longer 1¼" studs into the telescope's ring mount. (If you do not own MRS-5000 rings, 

use the shorter 7/8" long studs.)  Place the telescope down in the cradle so the studs go through the cradle holes.  Fas

-

ten in place with plastic knobs. 

Telescope Install on Gib HD4

• Tele Vue’s 4” scopes with clamshell-style ring. Start with the clamshell attached to the 

telescope. Make sure the bat handle and socket head screws on the clamshell are secured 

to prevent the telescope from sliding. Using the 1/8” Allen key, screw the 7/8" studs pro

-

vided into the 2 outer holes of the bottom half of the clamshell until they stop. (Be careful not 

to overtighten: clamshell is aluminum and threads may strip from excessive force multiplied 

by the leverage of the Allen wrench.) Place the telescope down into the mount’s cradle, so 

that the studs pass through the holes in the cradle base. Orient the scope so the vertical ten

-

sion knobs are closer to the telescope’s eyepiece end. Fasten in place with plastic knobs.

• Tele Vue’s 4” scopes with 4” Mount Ring Set MRS-4011. Unscrew the bat handles and 

socket head screws supplied with the Ring Set to remove the top rings and plate. Fasten 

base plate with bottom rings to the top of the mount cradle using the four ¼-20 button head screws supplied. Level the 

cradle and tighten the vertical tension knobs. Place the scope into the bottom rings. Replace the top-half of the Ring Set 

and reinstall the bat handles and socket heads to secure the scope. 

Balance and Use

• When mounting scope, orient tube so Vertical Tension Knobs are closer to the telescope's eyepiece end.

• Put a diagonal and eyepiece on the drawtube before balancing. Adjust vertical tension knobs so they have slight 

and equal tension.

• Swing the scope up approximately 45°. If the scope wants to swing up or down, level the scope and loosen the 

bat handles on one side of the ring. If the scope wants to swing back down, slide the scope backwards in the mount 

ring toward the vertical tension knobs. If the scope wants to swing up, push it forward so there is less tube between the 

mount ring and diagonal. Recheck balance and re-tighten the bat handles when balance is achieved. 

• Check the tension on the azimuth tension knob so the mount rotates smoothly. 

WARNING: Rotating the mount 

head while the azimuth tension knob is tightened could cause the azimuth bearing to unscrew and separate.

• Extra tension can be used to overcome a minor out-of-balance condition.  However, excessive tension will cause 

the movement to be “jerky.”  Severe overtightening could strip the threads in the mount head. 

• The most stable way of slewing your scope is by grasping a fixed part of the telescope, (i.e., focuser body), mount 

head or (optional Gib HD4) mount handle. Slewing the scope by holding the diagonal could cause slight image shift.

Additional Notes

• The safety chain is a safety device to prevent the legs from overspreading or collapsing when setting up the tripod 

for observing. It should remain on at all times. If the chain needs to be re-attached, slip each snap hook on the chain 

onto an eyelet on the inside of the leg-extension lock-knob brackets. 

• Gibraltar HD heads can be moved to a heavy-duty camera tripod by removing the mount stud. Use 5/64” Allen 

to loosen lower set screw on Azimuth bearing plate, and then unscrew the stud. Normally this set screw is tight to pre

-

vent stud from unscrewing from the head as mount is turned in azimuth.

Storage

• Before storing, if dew is present on the tripod, wipe it with an absorbent cloth and allow to dry for about 24 hours at 

room temperature. Do not place the tripod close to any direct source of heat as this will cause the wood to dry out unevenly. 

• If the tripod is set up and left standing in a low humidity room over a lengthy period of time, check the leg-extension 

lock knobs, and tighten them if necessary to prevent the tripod legs from collapsing.

• Each time you remove the tripod head, with attached top end-cap, the half pillar is unsupported and must be removed. 

Upon removal, make sure the stud coupling nut is threaded all the way down on the threaded rod and the setscrew on the 

side of the nut is secured to prevent the nut from turning. If the coupling nut is loose, or removed, attach it as follows: use a 

5/64” Allen key to back out the setscrew so the coupling nut can thread freely on the rod. With one hand below the tripod 

base, push the star lock knob up so the threaded rod passes through the half-pillar end cap. With the other hand, place the 

stud coupling nut, with the set-screw end facing down, onto the top of the threaded rod. Spin the star lock knob so it threads 

onto the stud coupling nut. The coupling nut will move down the top threaded part of the rod, pass through reduced shank 

and stop at the full shank on the other side. This should leave about ½” of available thread on the top of the coupling nut. 

Now tighten the setscrew on the side of the coupling nut with the 5/64” Allen key to prevent it from coming loose. 

• When storing the scope in a case with the mount rings and studs attached, screw the plastic knobs onto the studs to 

prevent ripping the foam liner. 

Gib HD5 Head 

Gib HD4 Head 

Reviews: