EN
23
9.1. Installation of the rack with
ventilation facilities
To facilitate the renewal and circulation of the
air inside the rack, and the temperature of the
units and thus improve their characteristics, it
is advisable to place 2 ventilation units of 25W,
particularly when the rack with the DVBS2-COFDM
T0X is located in warm place, with a temperature
higher than 45°C.
These ventilators will be installed on a tray that is
fi xed inside the cabinet (fi g. 1 & 2). This way, the
ventilators will be able to extract the air from the
DVBS2-COFDM T0X and will be able to expel it via
the gap (approx. 3-5 cm) at the top part of the Rack.
The air will enter again through the lower part of
the device, fi g 3.
9. Norms for rack mounting (max. 35 DVBS2-COFDM T0X - 7 subracks with 5 units in height - 8,7”)
Frontal
Subrack
fi g. 1
fi g. 2
fi g. 3