f. Temperature Menu
This menu shows the current measured
temperature, and the peak in º F.
The maximum value is stored in nonvolatile
memory and may also be reset by pressing and
holding the button for a few seconds.
The working temperature ranges displayed are the
following:
• Optimum temperature:
25 to 149 ºF
• Temperature is high:
150 to 184 ºF
• Temperature is excessive: > 185 ºF
The temperature accuracy is ± 1ºF.
In the event that the maximum temperature
recorded is outside the optimal range, the headend
installation should be modified to try to reduce its
ambient temperature, e.g. by mounting the units
inside a ventilated T.0X cabinet ref. 507202.
To check whether this change is effective, reset the
maximum temperature recorded and check again
its value after some working time has elapsed.
g. Version menu
This menu shows to the user the firmware versions
loaded in the processor.
h. Language menu
This menu allows to select the language used
to program the processor (Spanish / English /
German):
Select one of them by pressing buttons
and
.
5.3. Saving parameters
After setting up the unit by means of the two
menus available, main and extended, all data will
be saved by pressing the button for about 3
seconds.
The display shows:
Do not remove the programmer before the
message disappears from the screen.
If configuration data are changed but not saved,
previous settings will be restored after about 30
seconds. Therefore all changes made would be
cancelled.