Televes 563852 Quick Installation Manual Download Page 3

Important Safety Instructions

 

1.  Read and Follow All Instructions

 - All the 

safety and operating instructions should be 

read prior to and followed while operating 

this product.

2.  Retain Instructions

 - The safety and 

operating instructions should be retained 

for future reference.

3.  Heed Warnings - 

All warnings on the 

product and in the operating instructions 

should be adhered to. 

4.  Cleaning

 - Disconnect this product from 

any electrical source before cleaning. Use 

a damp cloth; do not use liquid or aerosol 

cleaners. 

5.  Attachments 

- Do not use attachments 

that are not recommended by the product 

manufacturer as they may cause hazards.

6.  Water and Moisture

 - Do not use this 

product near any source of water.

7.  Mounting – 

Do not place this product on 

an unstable cart, stand, tripod, bracket, 

or table. The product may fall, causing 

serious injury to persons or nearby objects, 

and serious damage to this product. Use 

only with a cart, stand, tripod, bracket, or 

table recommended by the manufacturer, 

or sold with the product. Any mounting 

of the product should follow the 

manufacturer’s instructions, and should use 

a mounting accessory recommended by the 

manufacturer.

 

 

8.  Ventilation 

– Slots and openings in 

the chassis or cabinet are provided for 

ventilation and to  ensure reliable operation 

of the product. These openings should 

never be blocked or covered in any way. This 

product should not be placed in any case, 

cabinet, or rack unless proper ventilation 

is provided and the manufacturer’s 

instructions have been adhered to.

 

9.  Power Sources 

- This product should be 

operated only from the type of power 

source indicated on the label.  

10.  Grounding or Polarization 

- Do not 

bypass or defeat electrical plug polarization 

or grounding. Doing so will violate the 

warranty and may pose a risk of fire or 

electrocution. 

11.  Wire Protection 

– Ensure all connected 

wiring is routed correctly to avoid damage 

including pinching, excessive bends, or 

compression.  

12.  Electrical Supply, Grounding, and Surge 

Protection – 

Ensure that all local or national 

electrical codes are followed. Seek the 

advice of a licensed electrician, professional 

engineer, or other licensed expert. 

13.  Power Lines

 - Always use caution and avoid 

operating this or any connected equipment 

near uninsulated power line or any other 

hazards. 

14.  Object and Liquid Entry 

- Never allow 

objects or liquid of any kind into this 

product through openings. Doing so could 

result in fire or electric shock. 

15.  Servicing 

- There are no user serviceable 

parts. Do not attempt to service this product 

or remove covers. Doing so may expose you 

to dangerous voltage or other hazards. Refer 

all servicing to qualified service personnel. 

Examples of damage requiring

 

service 

include but are not limited to:

 

y

Damage to power-supply wiring.

 

y

If liquid has been spilled, or objects have 

fallen into the product.

 

y

If the product has been exposed to rain 

or water.

 

y

If the product does not operate normally 

by following the operating instructions. 

Adjust only those controls that are 

covered by the operating instructions as 

an improper adjustment of other controls 

may result in damage and will often 

require extensive work by a qualified 

technician to restore the product to its 

normal operation.

 

y

If the product has been dropped or 

physically damaged.

 

y

When the product exhibits a distinct 

change in performance.

16.  Replacement Parts 

- Ensure that repairs are 

performed by qualified technicians and that 

only manufacturer supplied or authorized 

parts are used.

17.  Safety Check - 

Upon completion of any 

service or repairs to this product, ensure 

safety checks to determine that the 

product is functioning per manufacturer 

specifications are performed.

18.  Heat

 - The product should be situated 

away from heat sources such as radiators, 

heat registers, stoves, or other products 

(including amplifiers) that produce heat. 

Ensure that ambient temperature is 

maintained in the manufacturer specified 

operating range.

Safety instructions

Caution statements

Product inspection

 - Inspect the equipment 

for shipping damage. Should any damage be 

discovered, immediately file a claim with the 

carrier.

Important Safety Instructions

 - To ensure 

proper installation and operation, take a 

moment to read this guide before proceeding 

with the installation. If you have any questions 

or comments about the T.0X Series - Encoders, 

please contact your dealer.

WARNING:

 

TO PREVENT FIRE OR ELECTRICAL SHOCK 

DO NOT EXPOSE TO RAIN OR MOISTURE.

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVER.
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED 

PERSONNEL.

A product and cart combination should 

be moved with care. Quick stops, 

excessive force and uneven surfaces 

may cause the product and cart 

combination to overturn.

The lightning flash with arrow head 

symbol, within an equilateral triangle, 

is intended to alert the user to the 

presence of uninsulated “dangerous 

voltage” within the product’s enclosure 

that may be of sufficient magnitude 

to constitute a risk of electric shock to 

persons.

The exclamation point within an 

equilateral triangle is intended to 

alert the user to the presence of 

important operating and maintenance 

(servicing) instructions in the literature 

accompanying the product.

WARNING:

 

TO REDUCE THE RISK  OF FIRE OR 

ELECTRIC SHOCK, DO NOT EXPOSE THIS 

PRODUCT TO RAIN OR MOISTURE. 
DO NOT OPEN THE CABINET, 
REFER SERVICING TO QUALIFIED 

PERSONAL ONLY.

CAUTION:

TO PREVENT ELECTRIC SHOCK, DO NOT 

USE THIS (POLARIZED) PLUG WITH AN 

EXTENSION CORD RECEPTACLE OR OTHER 

OUTLET UNLESS THE BLADES CAN BE 

FULLY INSERTED TO PREVENT BLADE 

EXPOSURE.

Summary of Contents for 563852

Page 1: ...563852 w w w t e l e v e s c o m TWIN HDMI YPbPr IP MPEG2 4 ENCODER MODULATOR QAM COFDM IP EN QUICK INSTALLATION GUIDE GUÍA DE INSTALACIÓN RÁPIDA TWIN HDMI YPbPr IP MPEG2 4 ENCODER MODULADOR QAM COFDM IP ES ...

Page 2: ......

Page 3: ...rvice include but are not limited to y y Damage to power supply wiring y y If liquid has been spilled or objects have fallen into the product y y If the product has been exposed to rain or water y y If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls ma...

Page 4: ...llos controles que se indican en las instrucciones de uso ya que un ajuste incorrecto de otros controles puede resultar en daños y a me nudo requerirá intervención de personal cualificado para devolver el producto a su funcionamiento normal y y Si el producto se ha caído o dañado y y Cuando el producto muestra un cambio en su rendimiento 15 Piezas de repuesto Asegurarse de que las reparaciones son...

Page 5: ... Canal 1 3 Analog L R audio input Channel 1 Entrada audio analógica L R Canal 1 4 HDMI input Channel 1 Entrada HDMI Canal 1 5 SPDIF digital optical audio input Channel 1 Entrada audio digital óptica SPDIF Canal 1 6 SPDIF digital coaxial audio input Channel 1 Entrada audio digital coaxial SPDIF Canal 1 7 SPDIF digital coaxial audio input Channel 2 Entrada audio digital coaxial SPDIF Canal 2 8 SPDIF...

Page 6: ...mode Canal RF de salida encendido transmitiendo audio video modo normal Slow blinking green Verde parpadeo lento Carrier wave null or muted Portadora nulo o apagado Output RF channel is OFF or in an alternate signal mode Canal RF de salida está apagado o en un modo de señal alterno Solid orange red Naranja rojo fijo Normal Config bitrate doesn t fit in output El bit rate configurado no cabe en la ...

Page 7: ... posterior de los módulos las señales de entrada de audio y video Fig 2 3 Si dispone de una red que proporcione una dirección IP mediante un servidor DHCP conecte los encoders a la red como se indica en la Fig 3 Si la red no está disponible deberá usar un PC para la conexión como se indica en la Fig 4 4 Encienda las unidades 5 Conecte el programador a cada unidad y asigne un único número en el cam...

Page 8: ...lTransportStreamdesalida El TS ID SID y LCN de cada servicio no podrán coincidir con los de otro servicio de la misma unidad The Status Summary page Fig 7 should appear as the first page This provides a summary of all the units installed in the network and the units will be sorted by the number entered in Step 5 Fig 8 shows an example of a detailed status page 9 Configure all units Select CONFIGUR...

Page 9: ...e que no es una configuración válida y no le permitirá aplicar la configuración Una vez esté todo configurado pulse el botón Select asociado a Fig 13 IP 2 9 3 OUTPUT SettingtheRFoutputchannel Theunitwillrestart ifyouswitchbetween QAM and COFDM mode 9 4 IP The unit can work in 3 different modes IP Input Output and Disabled Input ToreceiveIPservices It snecessarythattheunitisinInputmode and you set ...

Page 10: ...seleccione CONFIGURATION Pulse en el nombre de la unidad y se mostrará la página de la Fig 15 Desde esta página puede modificar cualquier parámetro de la configuración de la unidad seleccionada each IP address and a window appears like Fig 13 If no appear any service wait until the end of the scan Here you can see the services available to the corresponding IP Selecttheservicesyouwanttodisplayandc...

Page 11: ...INPUT 1 2 Selected INPUT IP Selected RX Mode Only SID 1 1 1 SERVICE 1 00001 00003 IP MENU Enable edit mode Position cursor in edit mode Disable edit mode Activar el modo edición Posición del cursor en modo edición Desactivar el modo edición Change section Save parameters press and hold for 3 sec Cambiar sección Guardar datos pulse y mantenga pulsado 3 seg Change menu Modify value in edit mode Camb...

Page 12: ...ADRESS OUTPUT MUX 225 000 001 001 RTP OUTPUT 1 ENABLE RTP OUTPUT MUX ENABLE RTP OUTPUT 2 ENABLE OUTPUT IP OUTPUT 2 ENABLE N PACKETS OUTPUT 2 7 IP ADRESS OUTPUT 2 225 000 001 001 PORT NUMBER OUTPUT 2 01100 SELECT DEFAULT SETTINGS Hold key PORT NUMBER INPUT 1 01100 PORT NUMBER INPUT 2 01100 RTP INPUT 1 ENABLE RTP INPUT 2 ENABLE INPUT IP INPUT 2 ENABLE IP ADRESS INPUT 2 225 000 001 001 RX MODE DISABL...

Page 13: ... Roll off 15 Code Reed Solomon Spectrum Mode Normal Inverted Frequency Step KHz 250 COFDM Modulation format QPSK 16QAM 64QAM Guard Interval 1 4 1 8 1 16 1 32 FEC 1 2 2 3 3 4 5 6 7 8 Bandwidth MHz 6 7 8 Cell_id Editable Frequency Step KHz 125 166 IP MULTICAST Connectors 2x RJ45 Switch Gigabit Formats SPTS or MPTS UDP RTP PSI PARAMETERS Transport Stream ID Editable Original Network ID Editable Netwo...

Page 14: ...off 15 Código Reed Solomon Modo espectro Normal Invertedo Pasos de frecuencia KHz 250 COFDM Formato de modulación QPSK 16QAM 64QAM Intervalo de guarda 1 4 1 8 1 16 1 32 FEC 1 2 2 3 3 4 5 6 7 8 Ancho de banda MHz 6 7 8 Cell_id Editable Pasos de frecuencia KHz 125 166 IP MULTICAST Connectores 2x RJ45 Switch Gigabit Formatos SPTS o MPTS UDP RTP PARAMETROS PSI Transport Stream ID Editable Original Net...

Page 15: ... OF CONFORMITY DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ https doc televes com ...

Page 16: ...televes com ...

Reviews: