26

Put the fibre directly on the V-groove (V-shaped

groove) without fibre head (see image) and shut the fibre 

clamp.

Once the fibre is on the V-groove (V-shaped groove) enter 

the “Main menu” and go to the “CALIBRATE” option. Select 

this option and the fusion splicer will start calibrating.

The  screen  will  show  how  the  electric  arc  generates  and 

goes through the fibre.

After  around  10  seconds,  the  operation  will  come  to  an 

end. If the calibration was performed correctly, the screen 

will display “OK”. Otherwise, the screen will display the fo-

llowing text: “CALIBRATE AGAIN”.

NOTE: The fusion splicer will adjust to the calibration values 

in small steps after each splicing operation. However, after 

any environment changes, new calibration is required.

If the “Auto mode” function inside the “Settings” sub-menu 

is activated, you will be able to introduce one single fibre, 

and the calibration process will start automatically just by 

shutting the cover.

5.3 Turning the oven on

This function is used to manually run the oven’s program-

me. The oven’s programme is usually executed automati-

cally when a fusion is carried out (see previous page “Oven 

operation”), but under some circumstances you may wish 

to operate the oven, occasionally. If so, put the heat-shrink 

tubing in the oven compartment and push “TURN OVEN 

ON” in the menu. The oven will start working for the pro-

grammed duration (factory settings: 60 s. To change the 

duration, see section 6.3, “Oven”).

5.4 Settings

The  settings  menu  displays  the  following  functions  (see 

section 6, “Configuration”, for further details):

   Fibre selection

   Set time

   Oven

    Language

   Fibre position

 Electrodes

 Auto mode

   Start cleaning

   Pause fusion

5.5 Information

It  shows  different  kinds  of  information  about  the  fusion 

splicer.

*Electrode cleaning counter: Indicates the number of fu-

sions  carried  out  so  far  without  the  electrodes  having 

been cleaned (this number is reset once the electrodes are 

cleaned).

*Electrode  counter:  Indicates  the  number  of  fusions  ca-

rried out using the current electrodes (it resets when the 

function “ELECTRODES CHANGED” in menu “ELECTRODES” 

is executed).

* Total fusions counter: Indicates the total number of fu-

sions performed by the fusion splicer.

Hand-held fusion

Summary of Contents for 232130

Page 1: ...trucciones w w w t e l e v e s c o m Hand held fusion splicer EN Operating instructions Fusionneuse de poche FR Manuel d utilisation Giuntatrice palmare IT Manuale d utilizzo Handsplei ger t DE Bedien...

Page 2: ......

Page 3: ...rmation 21 2 Fusion splicer 22 3 Keyboard 23 4 Use 23 5 Main menu 25 6 Configuration 27 7 Advice for the appropriate handling of fibre 30 8 Cleaning 32 9 SD Card 33 10 Specifications 33 Hand held fusi...

Page 4: ...ot take the equip ment apart 4 Any errors in the external maintenance of the equip ment may cause fusion splicer malfunction or injuries to the maintenance operator carefully follow the mainte nance i...

Page 5: ...er no circumstances shall Televes be held responsible for damages or harm of any nature that could derive from this manual or the information contained in it Composition Hand held fusion splicer Fibre...

Page 6: ...22 2 Fusionadora 2 Fusion splicer Front view Top view Over SD card port Cover LCD screem USB port Cover Fibre clamp LCD screen keyboard Oven External changer connection Hand held fusion...

Page 7: ...the unit for at least 6 to 8 hours before using it for the first time Once charged for the first time bear in mind that this equipment allows you to recharge the battery while in use Turn on the fusio...

Page 8: ...fibre head inside the fusion splicer 4 Repeat steps 1 2 and 3 with the other fibre 5 Shut the fibre clamp Both fibre ends should be visible on the screen If necessary push the RESET button for the eng...

Page 9: ...pushing the SELECTION button 5 1 Electrode cleaning Run the ELECTRODE CLEANING programme to get rid of dirt and impurities on the electrodes An additional elec tric arc will be produced to burn any re...

Page 10: ...un the oven s program me The oven s programme is usually executed automati cally when a fusion is carried out see previous page Oven operation but under some circumstances you may wish to operate the...

Page 11: ...6 2 Set time Adjust date and time with the UP and DOWN buttons To go through year month day etc press the MOVE button Once you are done with the adjustment select EXIT to exit this function and save...

Page 12: ...rrect position see ima ge above the new position should be stored by pushing SELECTION on the SAVE option 6 6 Electrodes The ELECTRODES menu has the following options ADJUST In order to adjust the ele...

Page 13: ...resent VERY IMPORTANT Activating this option increases bat tery consumption and reduces electrode working life The fusion splicer regularly warns about the need to clean the electrodes after 10 fusion...

Page 14: ...nd 900 m fibre on the blue brackets See image Remember Not exchange heads between fusion split ters as previously indicated the fusion splitter is fac tory calibrated for heads supplied if they were e...

Page 15: ...above shows a deviation of the fibre possibly due to bad fibre positioning or to a dirty V groove If the fibre is aligned correctly but not appropriately centred check section 6 5 Fibre position to c...

Page 16: ...tioned method you can also clean the V groove with a cotton swab moistened with isopropyl alco hol Preferably combine both methods 8 2 Electrode cleaning The fusion splicer electrodes are sensitive an...

Page 17: ...the fibre prior to fusion Loss estimation after fusion Indication of the cutting angle of each fibre Time required for the fusion operation 7 seconds Time required for the heat shrink tubing adjustmen...

Page 18: ...televes com...

Reviews: