Technical specifications / Características técnicas

Mode

Modo

Boss  OFF  (Passive)

Boss  ON  (Active)

Operating band

Banda de trabajo

MHz

High VHF

174 - 216

UHF

470 - 698

High VHF

174 - 216

UHF

470 - 698

Gain

Ganancia

dBi

8.5

16

21 max.*

31 max.*

Output level

Nivel de salida

 ----

 Auto*

Noise figure

Figura de ruido

dB

---- 

2 typ

Power supply

Tensión de limentación

Vdc

0

12 - 24

Consumption

Consumo

mA

---- 

40 max

Beamwidth

Ancho de haz

º

30

Wind load

Carga al viento

N

120 (@ 80 miles/h)

165 (@ 93 miles/h)

*The gain is automatically adjusted according to the output level / La ganancia varía automáticamente en función del nivel de salida.

UHF

High-VHF

Televes USA LLC    

425 South Cherry Street, Suite 635     Denver, CO 80246       www.televes-usa.com       [email protected]      www.televes.com

Safety Instructions:

LIGHTNING PROTECTION

  If installed outdoors, be sure the antenna system is grounded 

so as to provide protection against voltage surges and built-

up static charges. Section 810 of the National Electrical Code 

ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54, of the 

Canadian Electrical Code, provide information with respect 

to proper grounding of the mast and supporting structure, 

grounding  of  the  antenna  lead-in  wire  to  an  antenna 

discharge  unit,  size  of  grounding  conductors,  location 

of  antenna-discharge  unit,  connection  to  grounding 

electrodes,  and  requirements  for  the  grounding  electrode 

(see figure and instructions).

   Mount the lightning arrestor or 75 ohm coaxial grounding 

block as close as possible to where the 75 ohm coaxial cable 

downlead enters the house. 

  The ground wires for both the mast and the downlead should 

be copper or aluminum wire, number eight (8) or larger. 

  The  downlead  wire  from  the  antenna  to  the  lightning 

arrestor and the mast ground wire should be secured to the 

house, spaced from four (4) to six (6) feet apart. 

   In the case of a “ground up” antenna installation it may not 

be necessary to ground the mast if the mast extends four 

or more feet in the earth. Consult a TV serviceman for the 

proper depth in your location. 

WARNINGS

  To prevent fire or shock hazard, do not expose the included 

power supply to rain or moisture. 

    Installation of off-air antennas near power lines is dangerous. 

For your safety, follow the installation instructions.

   Any alteration or modification to the product or usage not 

in accordance with product instructions voids the warranty.

Antenna Lead 

in Wire

Example of antenna grounding as per 

National Electrical Code, ANSI/NFPA 70

NEC - National Electrical Code

Ground 

clamp

Electric Service

Equipment

Ground clamps

Power service Grounding Electrode System 

(NEC Art 250, Part H)

Antenna Discharge Unit

(NEC Section 810-20)

(May substitute a 75 ohm 

Coax Grounding Block)

Grounding  Conductors

(NEC Section 810-21)