Banda de 

trabajo

Working 

band

MHz

470 - 698

CH 21 - 48 (EU)

CH 14 - 51 (USA)

Ganancia

Gain

dBi

13

Relación D/A

F/B ratio

dB

20

Carga al 

viento

Wind load

N

139

 

(1)

191,5 

(2)

Dimensiones

Dimensions

mm

in

807 x 560 x 206

31,77” x 22,05” x 8,11”

Peso

Weight

g

lb

1343

2,96

(1)

 80 miles/h - 130 Km/h     

(2)

 93 miles/h - 150 Km/h

ANSI/CEA

-2028-

A

Safety Instructions:

LIGHTNING PROTECTION

  If installed outdoors, be sure the antenna system is grounded so as to 

provide protection against voltage surges and built-up static charges. 

Section 810 of the National Electrical Code ANSI/NFPA70, or CSA 

C22.1 sections 10, 16, and 54, of the Canadian Electrical Code, provide 

information with respect to proper grounding of the mast and supporting 

structure, grounding of the antenna lead-in wire to an antenna discharge 

unit, size of grounding conductors, location of antenna-discharge unit, 

connection to grounding electrodes, and requirements for the grounding 

electrode (see figure and instructions).

   Mount the lightning arrestor or 75 ohm coaxial grounding block as close 

as possible to where the 75 ohm coaxial cable downlead enters the house. 

  The ground wires for both the mast and the downlead should be copper 

or aluminum wire, number eight (8) or larger. 

  The downlead wire from the antenna to the lightning arrestor and the 

mast ground wire should be secured to the house, spaced from four (4) 

to six (6) feet apart. 

   In the case of a “ground up” antenna installation it may not be necessary 

to ground the mast if the mast extends four or more feet in the earth. 
Consult a TV serviceman for the proper depth in your location. 

WARNINGS

  To prevent fire or shock hazard, do not expose the included power supply 

to rain or moisture. 

    Installation of off-air antennas near power lines is dangerous. For your 

safety, follow the installation instructions.

   Any alteration or modification to the product or usage not in accordance 

with product instructions voids the warranty.

Antenna Lead 

in Wire

Example of antenna grounding as per 

National Electrical Code, ANSI/NFPA 70

NEC - National Electrical Code

Ground 

clamp

Electric Service

Equipment

Ground clamps

Power service Grounding Electrode System 

(NEC Art 250, Part H)

Antenna Discharge Unit

(NEC Section 810-20)

(May substitute a 75 ohm 

Coax Grounding Block)

Grounding  Conductors

(NEC Section 810-21)

DECLARACIÓN DE CONFORMIDAD   DECLARATION OF CONFORMITY   DECLARAÇÃO DE CONFORMIDADE   DECLARATION DE 

CONFORMITE   DICHIARAZIONE DI CONFORMITÀ 

  DEKLARACJA  ZGODNOŚCI 

 KONFORMITÄTSERKLÄRUNG 

  ΠΙΣΤΟΠΟΙΗΤΙΚΟ 

ΣΥΜΜΟΡΦΩΣΗΣ 

 FÖRSÄKRAN OM ÖVERENSSTÄMMELSE 

 ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ 

 https://doc.televes.com

7

8

Horizontal assembly / Montaje horizontal

Reviews: