![Teletronics International WINC 900A Owner'S Manual Download Page 25](http://html1.mh-extra.com/html/teletronics-international/winc-900a/winc-900a_owners-manual_1082438025.webp)
25
Result codes:
OK
Valid parameter.
ERROR
Invalid value for selected register.
V - Verbal Result Codes
The ATV command determines whether the device sends a numeric digit (terse mode) or an
informative text string (verbose mode).
Format:
ATV0
Use numeric result codes.
ATV1
Use text string result codes.
Result codes:
OK
Valid argument.
ERROR
Invalid argument.
Below is a listing of numeric and text string result codes:
Numeric Code
Text String Response
0
OK
1
CONNECT
2
RING
3
NO CARRIER
4
ERROR
6
NO DIAL TONE
7
BUSY
8
NO ANSWER
X - Extended Result Codes
The ATX command determines whether the device enables extended result codes. All extended result
codes are enabled in the default settings.
Format:
ATX0
Enable only codes 0...4. Extended results are mapped as
appropriate to 0...4.
ATX2
Enable all extended result codes (default).
Z - Soft Reset
The ATZ command resets all parameters to the saved profile, aborting any active connection. If no
profile was saved, the device is reset to the default condition.
Format:
ATZ
Perform soft reset.
Result code:
OK
Command complete.
&C - Set DCD Operation