The Complete Kit Contents 

• 

An outdoor unit, the UDC5800 

• 

DC injector 

• 

Universal power supply, and 

• 

Mounting hardware. 

Installation  

As shown in the above diagram power is carried to the UDC from DC Injector via RF cable.  The 
DC injector is an indoor unit and requires weather protection.  The UDC is installed at the antenna 
pole (or mast) with the U-bolt assembly. It is a weatherproof unit and designed to withstand the 
outdoor environment. Since the UDC5800 is built with lightening protection circuitry, it is extremely 
important to ground the whole unit. A grounding cable can be tightened directly to the U bolt. This 
would not only ground any lightening strike on the antenna but would also relieve it from any static 
built-up in the environment during bad weather.  
 

Once the unit is installed and tested, all the N connectors must be waterproofed with electric tape or any other sealant.  

 

/

   Caution  

1. 

The RF cable between the DC Injector and the UDC carries DC power, make sure it is NOT 

shorted to ground; OR DC Injector could be permanently damaged. 

2. 

If this cable is accidentally connected to “To Antenna” connector on the UDC (since it has 
lightening protection with DC ground), the DC Injector could be permanently damaged. 

 