Proximity reader
The TELETASK proximity reader is an AUTOBUS interface which gives secured access. An
access card or key tag, held briefly in front of the proximity reader, gives access (if allowed).
Beside of unlocking a door or opening a gate, the system can activate any other home
automation function. The person can be in the system as a member of a group like ‘family’,
‘employee’, ‘gardener’, etc…which all have specific group rights and additional functions. The
door opens and specific lights are activated (if dark), room temperature settings can be
changed, wall sockets activated, email /SMS sent to xyz, etc… TELETASK offers security
with extra smart controls and access logging information stored for later use in a computer
sheet (e.g. employee registration)..
APPLICATION
For a safe contactless access control in combination with any
other control of a domotic function. Cards and key holder TAGs
can have limited access: between certain hours of the days,
only on certain days or any other condition that you want.
CHARACTERISTICS
General
The proximity reader fits the needs and protection for indoor
installation. In outdoor application it is necessary to seal the
back with silicone (between back and wall) against water
infiltration at the AUTOBUS connector.
Adding, deleting and changing the access parameters of each
proximity card/TAG is possible using PROSOFT V2.74 or
higher (with the integrated CARDSOFT software).
Cleaning
Use only dry microfiber cloth. Never use liquids or solvents!
LED Feedback
TDS12142xx Connected: LED blinks slowly
Connection error: LED blinks fast
Card or TAG detected: LED will be ON for 2 sec
The PORTA app
All access events are logged in real time and stored in the
central unit memory. With the access app (PORTA or replaced
by ATMOS app from Q4 2022), the owner can check the given
and denied access events on his smartphone, tablet and pc.
The PORTA app gives you all the necessary access
information.
!
For privacy reasons, by default, the family members are not
logged by the TELETASK system, but you can activate the
access log of individuals when you like.
!
Important: The local privacy regulations need to be checked by
the system integrator to make sure that the individual app
configuration complies with them.
Configuration
Via PROSOFT Suite 2.74 or higher.
AUTOBUS address
Through rotary switches Tens + Units
Jumpers
Terminating resistor (supplied with the central unit). To be used
when the interface is at the physical end of the AUTOBUS
cable.
INSTALLATION
On-wall mounting in front of any wall box or hole, to contain the
AUTOBUS cable and connector.
When the proximity reader is placed in unsheltered outside
locations it is necessary to add silicone between the wall and
the housing as shown in the mounting drawing.
!
This proximity reader auto calibrates itself immediately
after power up. Therefore, always disconnect the (central)
AUTOBUS for 5 seconds after final installation without
removing the device from the wall.
!
The mounting distance between two proximity readers should
be 1 meter minimal. Also when two readers are placed back-to-
back on a wall, this is an important minimum.
SETTINGS
Jumpers
Jumpers Terminating resistor (supplied with the central unit).
To be used when the interface at the physical end of the
AUTOBUS cable.
CONNECTIONS
AUTOBUS
AUTOBUS connector set + (supplied with the interface). 12V
(supplied by the AUTOBUS - minimum 9V). Can be checked in
PROSOFT diagnostics.
POWER CONSUMPTION
Max. 50 mA
DIMENSIONS
TDS12142PN
115 H x 115 W x 15 D (mm) (on top of the wall)
Radius edges: 13mm
TDS12142GL and TDS12142GB
115 H x 115 W x 18 D (mm) (on top of the wall)
Radius edges: 13mm
NET | GROSS WEIGHT
TDS12142PN
0,137 | 0,247 kg
TDS12142GL and TDS12142GB
0,147 | 0,257 kg
PACKAGING CONTENT
TDS12142xx
AUTOBUS connector set
STORAGE
Temperature
-20°C to +65°C
Relative humidity
15% to 85%