background image

M o d e m s

M o d e m s

MIU/PowerPort can be powered by deli5VDC (regulated) through pin 10 of the DB25. An optional 7-16VDC version is

also available. Alternatively, an external jack allows the MIU/PowerPort to be powered from a wall transformer or other

low voltage AC or DC power source.

When not on line, the dial-up MIU/PowerPort modems automatically go into a power down mode and consume only a few

microamps while inactive.

The MIU/PowerPort operates over dial and 2-wire/4-wire leased lines at full or half duplex as appropriate with various

modulations, including: 

• Bell 202T

(1200bps)

• V.22bis

(2400bps)

• V.32bis

(14400bps)

The MUI/PowerPort is fully Hayes™ AT command set compatible with programmable S-registers.

All models will operate in temperatures from -40°C to +85°C and are surge protected on the analog line up to 5kV.

MIU/PowerPort 

LOW VOLTAGE, DC 

POWERED MODEMS

1.2, 2.4, 9.6 & 14.4 kbps

Bell 202T, V.22bis, V.32bis

Dial-Up and Leased Lines

Powered from 5-24VDC through the Data Port 

or an External Jack

Automatic “Power Down” when inactive

-40°C to +85°C Operating Temp.

Hayes AT Compatible

Ideal for Meters, Relays, RTUs, Controllers, etc.

The MIU/PowerPort is an industrial grade
modem that is designed to be powered
directly through the RS232 (DB25) data
interface port.

Reviews: