Appendix E –10K JLTX Transmitter (Continued)
E-2.1.2. SW3 Position 7 Tilt Switch Enable –
(Turn “ON” to enable tilt switch for those
units so equipped).
Switch SW3-position 7 turn “ON” to enable Tilt
Switch.
E-2.1.3.
SW3 Position 8 Time-out-timer
Disable. (Normally keep turned “OFF”).
The transmitter has an approximate 15-minute
time-out-timer. If the transmitter is not used for
over 15 minutes it will shut down. This
transmitter time-out-timer function is transmitter
dip switch selectable. SW3 position 8 disables
the time-out-timer. Turning SW3-8 “ON”
disables the time-out-timer.
E-2.2. Transmitter
Switch Programming for
Switch SW4.
E-2.2.1.
SW4 Position 1-2 Mode Enable.
(Standard Mode 1 keeps 1-2 turned “OFF”).
E-2.2.1.1.
SW4 Position 1-2 Mode Enable.
10K12 Systems.
Mode 1, SW4 1-2 all “OFF”. The 10K12 single
speed system comes standard configured this
way from the factory with three motion controls
and six auxiliaries (controlled by the toggle
switches). The 10K12 2-speed system comes
standard configured this way from the factory
with three 2-speed controls and three auxiliaries
(controlled by the toggle switches, the rotary is
non-functional).
Mode 2, SW4 1 turned “OFF” and SW4 2 turned
“ON”. The 10K12 2-speed system configured
this way is able to control four 2-speed motion
controls and no auxiliaries (bridge, trolley, main
and aux hoist). The rotary selector switch
functions are H1 main hoist, H2 aux hoist and B
both main and aux hoist (the toggle switches are
non-functional).
Mode 3, SW4 1 and 2 turned “ON”. The 10K12
2-speed system will control up to 5 motors using
the rotary selector switch. This mode
reconfigures two of the 10K12 auxiliary outputs
(Aux 1 and Aux 2) to be external motor select
functions by the rotary switch. In this mode the
auxiliary toggle switch Aux 1 and Aux 2 is
disabled. When the rotary switch is in the H1 or
H2 position Aux 1 relay or Aux 2 relay will pull
in respectively whenever trolley or hoist
pushbuttons are pressed. When the rotary switch
is in B position both Aux 1 and Aux 2 relays will
pull in.
E-2.2.1.2.
SW4 Position 1-2 Mode Enable.
10K16-24 Systems.
Mode 1, SW4 1-2 all “OFF”. The 10K16 3-speed
system comes standard configured this way from
the factory with three 3-speed controls and four
auxiliaries. The 10K24 3-speed system comes
standard configured this way from the factory
with five 3-speed controls and four auxiliaries.
Mode 2, SW4 1 turned “ON” and SW4 2 turned
“OFF”. The 10K24 configured this way gives
hoist, trolley and bridge with independent select
functions. The system utilizes separate select
relays with common speed and direction.
Mode 3, SW4 1 turned “OFF” and SW4 2 turned
“ON”. The 10K24 configured this way is four
motor 3-speed selectable by the rotary switch.
Two hoists, one trolley and one bridge with main
hoist (H1), auxiliary hoist (H2), and “both” (B)
main and auxiliary hoists are selectable by the
rotary switch.
E-2.2.2. SW4 Position 3 Disable Tandem for
hoist and trolley. (Normally keep turned
“OFF”).
For cranes with auxiliary hoists and/or trolleys,
turning this switch “ON” disables the transmitter
selector switch “B” position (both function) that
selects tandem operation of hoist or trolley.
E-2.2.3. SW4
Position 4 Invert Crane Select
Aux. Outputs. (Normally keep turned
“OFF”).
For cranes that use the select function only,
turning this switch “ON” inverts the select
function operation so that the relay closes for the
unselected function.
E-2.2.4. SW4 Positions 5-7 Extended Crane
Control.
E-2.2.4.1. SW4 Positions 5-7 Extended
Crane Control for Stepped Systems.
(Standard all “OFF”).
The 10K JLTX transmitter is available with
extended crane control configurations. These
options are switch configurable on the
transmitter. The eight-position dip switches SW3
E-3