In order to ensure proper operation of IDH2-3308, there are some requirements for other digital TV and 

network devices, which will connect with IDH2-3308. Please see below for details: 

2

2

.

.

1

1

.

.

1

1

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

 

 

f

f

o

o

r

r

 

 

D

D

i

i

g

g

i

i

t

t

a

a

l

l

 

 

T

T

V

V

 

 

D

D

e

e

v

v

i

i

c

c

e

e

s

s

 

 

The  preceding  device  of  IDH2-3308  needs  to  provide  Standard  Definition  AV/SDI  signal  source.  The 

succeeding device of IDH2-3308 need to receive ASI/IP signal derived from IDH2-3308. If modulator is 
used later, the terminal STB and this modulator should be agreed with the same DVB’s transmission 
standard.   

Administer should properly configure the input and output settings for IDH2-3308. 

2

2

.

.

1

1

.

.

2

2

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

 

 

f

f

o

o

r

r

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

e

e

v

v

i

i

c

c

e

e

s

s

 

 

The  switch  for  the  IDH2-3308  and  the managing workstation  should  be  a  100M  or  gigabit  switch,  the 

maximum data exchange speed of each port must be higher than 60Mbps.   

 

Any hosts that may worsen the network traffic, such as some workstations or servers installed real-time 

communication tools, streaming media server or WEB server, must not be located at the LAN switch of 

the output of IDH2-3308. These additional signals may cause packet loss, network jitter worsening, and 

hence due to audio/video distortion at the audiences. 

2

2

.

.

2

2

 

 

 

 

R

R

e

e

m

m

a

a

r

r

k

k

s

s

 

 

Management workstation must contain network device such as network card. Microsoft Windows are the 

recommended operating systems of the management workstation. 

 

The using value of parameter settings should comply with the criteria below: 

 

Parameter Settings 

Value Range 

Note 

Video Output Bit Rate 

 

0.25

5.5Mbps (H.264) 

0.5

5.5Mbps (MPEG-2) 

Channel 1

Video Bit Rate Mode 

CBR/VBR 

Channel 1

Video Encode Standard 

H.264/MPEG-2 

Channel 1

Profile Mode   

High profile/Main profile 

 

Video Input Format 

A/V:PAL60/SECAM/NTSC4.43/PAL(COMBINATION-

N)/PAL(M)/PAL(D/K/B/G/H/I/N)/NTSC(M/J) 

SDI:PAL/NTSC 

Channel 1

Summary of Contents for IDH2-3308

Page 1: ...MODELIDH2 3308 ...

Page 2: ...s for connecting network interfaces of the device 8 Avoid rapid and frequent power on off or it may cause damages to the semiconductor chipsets 9 Keep proper direction of the power cord when plug into or out from a power socket 10 Do not touch the power socket with wet hands to avoid electric shocks 11 Take off all jewelry or ornaments such as ring necklaces watches bracelets etc before operating ...

Page 3: ... Management 11 3 2 2 1 Create New Users 12 3 2 2 2 User Edit 13 3 2 2 3 Delete Existing Users 13 3 2 3 Connecting Device 14 3 2 3 1 Device Information 14 3 2 3 2 Warning Information 14 3 2 4 Parameter Settings 16 3 2 4 1 Encode Parameter Settings 16 3 2 4 2 Program Parameter Settings 17 3 2 4 3 Multiplex Settings 18 3 2 4 5 3 Output Parameters Setting 24 3 2 5 Device Management Settings 25 3 3 Fro...

Page 4: ... 5 5 5Mbps MPEG 2 G Support VBR CBR video encoding H Video aspect ratio support 4 3 16 9 1 1 I Support MEPG 1 L2 or LC AAC audio encode format J MPEG 1 L2 audio sampling support 192Kbps 224Kbps 256Kbps 320Kbps 384Kbps K LC AAC audio sampling support 96Kbps 112Kbps 128Kbps 160Kbps 192Kbps 224Kbps 256Kbps 320Kbps L Support audio sample rate 32KHz 44 1KHz 48KHz M System output data rate range 2 60Mbp...

Page 5: ... data1 one RJ45 connector for management one engineering test port one power supply connector one power switch and a grounding connector 1 Power Input Port To connect to 100 240V 50 60Hz AC input 2 Power Switch To turn IDH2 3308 on or off 3 CNOTROL Management Port RJ45 interface to connect to management server via 100BaseT or Gigabit Ethernet 4 CONSOLE port engineering test port Do not use as mana...

Page 6: ...formats The input devices of IDH2 3308 should be A V output devices such as satellite receiver video player DVD etc the output connection devices of IDH2 3308 should be multiplexer and scrambler Remark We strongly recommend use of TELELYNX products as IDH2 3308 s input and output signal processing devices as the reliability of their unified performance is proven For products of other manufacturers...

Page 7: ...h for the IDH2 3308 and the managing workstation should be a 100M or gigabit switch the maximum data exchange speed of each port must be higher than 60Mbps Any hosts that may worsen the network traffic such as some workstations or servers installed real time communication tools streaming media server or WEB server must not be located at the LAN switch of the output of IDH2 3308 These additional si...

Page 8: ... 1 8 no SDI HUE 0 100 Channel 1 8 no SDI Image Horizontal Offset 0 40 Channel 1 8 no SDI Video PID 0x20 0x1ffe Channel 1 8 No PID value conflict Audio PID 0x20 0x1ffe Channel 1 8 No PID value conflict PCR_PID 0x20 0x1ffe Channel 1 8 No PID value conflict except video PID PMT_PID 0x20 0x1ffe Channel 1 8 No PID value conflict Program Name 16 letters or 8 Chinese characters character range A Z a z 0 ...

Page 9: ... Subnet Mask 000 000 000 000 255 255 255 255 Default Gateway 000 000 000 000 255 255 255 255 Language Selection Chinese English IP Output Program Type MPTS SPTS IP Output Module Source IP Address 000 000 000 000 255 255 255 255 IP Output Module Destination IP Address 000 000 000 000 255 255 255 255 IP Output Module IP Network Subnet Mask 000 000 000 000 255 255 255 255 IP Output Module UDP Port 1 ...

Page 10: ...ed configuration 4 Boot up IDH2 3308 perform a factory reset through the front panel control If you have known the management port IP address of the IDH2 3308 you are currently using and it is in the same subnet with the management workstation you may also start configuring IDH2 3308 from the management workstation directly Or otherwise you will need to configure the IP address of management port ...

Page 11: ... 3308 through web NMS To ensure the device security you should enter the username and password as shown in the figure below There is a factory default administrator account admin with password of 000000 Please use this account and password to login to the system for the first time operation of IDH2 3308 But changing of password for this account is strongly recommended and the new password should b...

Page 12: ... new password and then confirm the password click submit to add a new user account Remark 1 All the accounts created are common users 2 Common user can do system configuration but is not allowed to perform task such as user management and system upgrade 3 Username and password should be limited within 3 to 32 letters all the string characters are available including letter number and other symbols...

Page 13: ...dified 2 When using IDH2 3308 for the first time password of admin account should be modified firstly and kept them safely 3 The modified password should be limited within 3 to 32 letters all the string characters are available including letters number sand underlines 3 3 2 2 2 2 3 3 D De el le et te e E Ex xi is st ti in ng g U Us se er rs s In the default page click button of any user account to...

Page 14: ...e Information button in upper navigation bar will enter the page of device information as shown in the figure below Device Information This device information bar will show the following information in sequence serial No hardware version software version FPGA release version as well as working mode input port input format output validated bit rate and temperature of each encode channel 3 3 2 2 3 3...

Page 15: ... encountered these common Warning information as follows please refer to Annex C frequently asked questions Common Warning information in channel 1 No signal input 2 Coding error Common Warning information of ASI input 1 No signal input Common Warning information of output status 1 Buffer overflow Common Warning information of system status 1 FPGA load failure 2 Temperature exceed the threshold ...

Page 16: ...meters will be shown for modification as shown in the figure below Encode Parameter Settings 1 Video format of channel 1 8 A V PAL60 SECAM NTSC4 43 PAL COMBINATION N PAL M PAL D K B G H I N SDI PAL NTSC 2 Video resolution of channel 1 8 PAL 720 576 704 576 640 576 544 576 352 576 NTSC 720 480 704 480 640 480 544 480 352 480 3 Video bit rate mode of channel 1 8 CBR VBR 4 Video encode mode of channe...

Page 17: ...annel 1 8 32 8190 19 Audio PID settings of channel 1 8 32 8190 20 PCR PID settings of channel 1 8 32 8190 21 PMT PID settings of channel 1 8 32 8190 3 3 2 2 4 4 2 2 P Pr ro og gr ra am m P Pa ar ra am me et te er r S Se et tt ti in ng gs s Click Program Parameters hyperlink in the navigation bar to enter the page for setting of program parameters as shown in the figure below Program Parameter Sett...

Page 18: ...eft selection items of multiplexer configuration include input service information and output service information 3 3 2 2 4 4 4 4 I In np pu ut t S Se er rv vi ic ce e As shown in fig 13 click the button in front of Input Service Info to unfold its sub menu shown as below Input Service Info As shown in fig 14 click any lick e g Encoder Service to enter the page of encoder service information shown...

Page 19: ... 3 2 2 4 4 4 4 1 1 P Pr ro og gr ra am m S Se ea ar rc ch h As shown in fig 15 system will automatically analyze and show the input service information by clicking of Service Analyse button shown as below 5 Input Service Info ...

Page 20: ... 4 4 4 4 3 3 S Si in ng gl le e P Pr ro og gr ra am m M Mu ul lt ti ip pl le ex xi in ng g Select ON from the dropdown list of Mux Status of the program to multiplex it shown as below 6 TS Info of Program Click the submit button to complete the multiplexing 3 3 2 2 4 4 4 4 4 4 B Ba at tc ch h P Pr ro og gr ra am m M Mu ul lt ti ip pl le ex xi in ng g IDH2 3308 supports batch program multiplexing I...

Page 21: ...ton to complete the batch multiplexing 3 3 2 2 4 4 5 5 O Ou ut tp pu ut t S Se er rv vi ic ce e As shown in figure 13 click button in front of Output Service Edit to unfold the output service channel shown as below 8 Output Channel Menu As shown in figure 21 click output service button to enter the output TS setting page shown as below ...

Page 22: ...nformation such as TS ID ON ID PAT version etc 3 3 2 2 4 4 5 5 2 2 P Pr ro og gr ra am m I In nf fo or rm ma at ti io on n E Ed di it t IDH2 3308 allows users to edit each individual program information Click button at the front of the service name to open the program information 10 Program information Editable information include service name service number service provider PMT information PCR PI...

Page 23: ...he value of PCR PID in the corresponding box and click Submit button to validate the setting PMT descriptor PMT Descriptor To edit the PMT descriptors click the Edit then the Descriptor Type box at the button of the page will display Service PMT Descriptors shown as below Edit PMT Descriptor Click add button to edit the PMT descriptor Edit PMT Descriptor The enable drop down list controls the tran...

Page 24: ...meters including IP output parameters 3 3 2 2 4 4 5 5 4 4 I IP P O Ou ut tp pu ut t P Pa ar ra am me et te er r S Se et tt ti in ng gs s IP Output Parameter Settings The output parameters that can be configured in this page are as follows 1 IP output mode MPTS SPTS 2 IP address of channel 1 8 and output port settings should comply with standard IPV4 3 UDP RTP port of channel 1 8 1 65535 Remark 1 W...

Page 25: ...tput Parameter Settings Click the sub node of Output Parameters hyperlink in the left side of page the related parameters of ASI output can be set or checked in the right side of window including 1 Output bit rate according to your required encoding quality and available channel bandwidth configure it from the range of 2000 Kbps to 60 000Kbps buffer overflow alarm will be shown when output bit rat...

Page 26: ... Setting 4 Output charset settings ASCII ISO 9959 5 Cyrillic GB 2312 Unicode UFT 8 Unicode UCS 2 BE Unicode UCS 2 LE 5 Import system configurations it provide the user with a quick way to set by using the existing parameter file 6 Mux status ON OFF 7 Ayalyse timeout ms Adjust the accuracy of mux analyze with range of 800 30 000ms Import method 1 Click Browse button of Import System Configurations ...

Page 27: ...ng 2 Click Import button it will show the page below after the import process successfully completed Confirm Parameter Upload Remark 1 If File Upload shows failed then file uploading is failed and it may be caused by network connection please check the network connection and upload the file again 2 If File Check shows failed then file checking is failed and it is possible that you upload a illegal...

Page 28: ...s of new software or eliminate the problems caused by the previous version please use the upgrade packet we provided to upgrade wrong packet may cause the improper operation of device H Parameter reconfiguration we recommend you reconfigure the parameters if parameter abnormality occurred to reset settings to the factory defaults I Reset device Remark In order to ensure the proper operation of sys...

Page 29: ...12 31 23 59 59 3 0 IP Address 192 168 001 010 3 1 Subnet Mask 255 255 255 000 3 2 Default Gateway 192 168 001 001 3 3 MAC Address 5445XXXXXXXXXXXX 5 0 Language CHN ENG 4 0 Parameter reconfiguration Yes No 2 5 Hardware Version XX XX 1 0 Alarm 01 Code C0001 255 Device Model Device Name 4 1 Factory Reset Yes No 1 0 Alarm 02 Code W0002 255 1 0 Alarm 03 Code I0002 255 1 0 Alarm Clean Alarm of Front Pan...

Page 30: ...aces Characteristic Properties Specifications Video Input Interface Video Format PAL60 SECAM NTSC4 43 PAL COMBINATION N PAL M PAL D K B G H I N optional Physical Connector BNC Female Electrical Specification Impedance 75Ω Video Bandwidth 25Hz 5 75MHz CPL 1 0Vp p Quantification 10bits Comply with CCIR 601 Sampling Frequency 27MHz Audio Input Interface Physical Connector BNC Female Electrical Specif...

Page 31: ... Connector RJ45 Communication Protocol TCP IP Data Rate 100Mbps IP OUT Output Interface Physical Connector RJ45 Communication Protocol UDP RTP Data Rate 100Mbps A 3 TS Re multiplexing Characteristic Properties Technical Specification Output Programs Output No of Programs 1 8 Output TS s PSI Information Standard Syntax ISO IEC 13818 1 Table Type PAT PMT SDT Automatically Generate ...

Page 32: ...nnel 1 8 Audio Bit Rate 192Kbps Channel 1 8 Volume 0dB Channel 1 8 Audio Sampling Frequency 48KHz Program 1 8 Video PID 128 129 130 131 132 133 134 135 Program 1 8 Audio PID 144 145 146 147 148 149 150 151 Program 1 8 PCR_PID 160 161 162 163 164 165 166 167 Program 1 8 PMT_PID 176 177 178 179 180 181 182 183 Program 1 8 Program Name PROGRAM1 PROGRAM2 PROGRAM3 PROGRA M4 PROGRAM5 PROGRAM6 PROGRAM7 P...

Page 33: ...2 1005 Destination IP6 Address of IP 1 2 88 88 88 51 IP6 UDP Port of UP1 2 1006 Destination IP7 Address of IP 1 2 88 88 88 51 IP7 UDP Port of UP1 2 1007 Destination IP8 Address of IP 1 2 88 88 88 51 IP8 UDP Port of UP1 2 1008 Data Port MAC Address 00 5c b1 00 xx xx xx xx based on serial No and only the specific users can modify Data Port IP Address 88 88 88 50 Data Port Subnet Mask 255 255 255 0 D...

Page 34: ... if the input signal format can recognized by IDH2 3308 Fail to scan any input programs Improper connection of BNC cable at data input Check if the cable is properly connected BNC cable problem Check if the cable is properly worked or change the cable Fail to scan programs in specific input Source device is not working properly Check malfunction in the source device IP output succeeding device can...

Page 35: ...error bit appears in all IP output programs Other data flow in network too large Clear the other data flow in network and it is best to remove other irrelevant hosts Abnormal color or shaking screen in encoding output program Incorrect input video format Ensure that input video format is corresponds to actual input format Alarm prompts that system error Hardware components of device damaged Return...