Telegesis
TG-EAPE-PM-006-102 4
EAP-E
Product Manual
1.02
2 Absolute Maximum Ratings
Parameter
Min.
Max.
Units
Condition
Supply Voltage Vdd
-0.3
20
1
V
Storage Temperature range
-40
85
°C
Table 1. Absolute Maximum Ratings
The absolute maximum ratings given above should under no circumstances be violated.
Exceeding one or more of the limiting values may cause permanent damage to the device.
3 Operating
Conditions
Typical values at 25°C.
Parameter
Min.
Typ.
Max.
Units
Condition
Supply Voltage, Vdd
4.5
5
6
V
235
275
mA
TX +3dBm
Supply Current
EAP-E
235
275
mA
RX
300
400
mA
TX +17dBm
Supply Current
EAP-E-PA
235
275
mA
RX
Operating ambient
temperature range
0
25
70
°C
Table 2. Operating Conditions
For radio features please refer to the ETRX2 and ETRX2-PA product manuals.
Dimensions: 114mm x 74mm x 25mm
Weight: 95g
1
Thermal shutdown may occur when exceeding the operating conditions. The unit will become operational
again after allowing it to cool down.
©2008 Telegesis (UK) Ltd