2  Absolute Maximum Ratings 

 
 

Parameter 

Min. 

Max. 

Units 

Condition 

Supply Voltage Vdd 

-0.3 

20

1

 

 

Storage Temperature range 

-40 

85 

°C 

 

Table 1.  Absolute Maximum Ratings 

 
 
The absolute maximum ratings given above should under no circumstances be violated.  
Exceeding one or more of the limiting values may cause permanent damage to the device. 
 
 
 
 

3 Operating 

Conditions 

 
Typical values at 25°C. 
 

Parameter

 

Min. 

Typ. 

Max. 

Units 

Condition 

Supply Voltage, Vdd 

4.5 

 

 

235 

275 

mA 

TX +3dBm 

Supply Current 
EAP-E 

 

235 

275 

mA 

RX 

 

300 

400 

mA 

TX +17dBm 

Supply Current 
EAP-E-PA 

 

235 

275 

mA 

RX 

Operating ambient 
temperature range 

25 

70 

°C 

 

Table 2.  Operating Conditions 

 
For radio features please refer to the ETRX2 and ETRX2-PA product manuals. 
 
Dimensions: 114mm x 74mm x 25mm 
 
Weight:  95g 
 

 

                                                 

1

 Thermal shutdown may occur when exceeding the operating conditions. The unit will become operational 

again after allowing it to cool down. 

©2008 Telegesis (UK) Ltd 

 

EAP-E Product Manual (Rev 1.02) 

Summary of Contents for EAP-E

Page 1: ...Telegesis TG EAPE PM 006 102 1 EAP E Product Manual 1 02 TG EAPE PM 006 102 EAP E and EAP E PA Ethernet Access Point PRODUCT MANUAL Telegesis 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Page 2: ...S 4 3 OPERATING CONDITIONS 4 4 DEVICE INSTALLATION AND OPERATION 5 4 1 Creating Virtual COM Ports 7 5 FIRMWARE CHANGES AND UPGRADES 11 5 1 Device Reset and manually Entering the Bootloader 11 6 SCHEMA...

Page 3: ...e to connect to one or more local EAP Es via the internet allowing remote interaction with local ZigBee networks Using the Ember bootloader custom firmware and firmware upgrades can be downloaded via...

Page 4: ...Conditions Typical values at 25 C Parameter Min Typ Max Units Condition Supply Voltage Vdd 4 5 5 6 V 235 275 mA TX 3dBm Supply Current EAP E 235 275 mA RX 300 400 mA TX 17dBm Supply Current EAP E PA 2...

Page 5: ...his simply follow these steps 1 Install and execute the Lantronix DeviceInstaller 2 If your PC has more than a single network adapter a message will prompt at start up requiring you to specify which a...

Page 6: ...respective port of the corresponding local EAP Es All you need now to connect to your ZigBee network via the internet is the remote IP address and the port number Figure 3 A Telnet Session to the EAP...

Page 7: ...drate flow control parity data bits identical settings must be used for the Lantronix XPort DirectTM and the ETRX2 otherwise communication will not be possible For a detailed description of the menu s...

Page 8: ...ese simple steps 1 Download and Install the Lantronix CPR 2 Make sure your EAP E is installed and correctly configured 3 Execute the CPR Manager 4 Select Device Search All EAP Es in the local network...

Page 9: ...duct Manual 1 02 Figure 5 The Lantronix CPR After this process any application can access the embedded ETRX2 as though it was connected to the local machine s COM port as shown in Figure 6 2008 Telege...

Page 10: ...Telegesis TG EAPE PM 006 102 10 EAP E Product Manual 1 02 Figure 6 Telegesis Terminal accessing a EAP E using CPR 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Page 11: ...esis Terminal Use DeviceInstaller to change Lantronix module back to 19200 baud Connect Telegesis Terminal Resume normal operation with new firmware Alternatively access to the SIF programming interfa...

Page 12: ...h are not fitted The serial port including the handshaking lines as well as the reset and A D2 lines can be accessed via labelled pads X2 is the SIF connector which allows programming and custom firmw...

Page 13: ...Telegesis TG EAPE PM 006 102 13 EAP E Product Manual 1 02 2008 Telegesis UK Ltd EAP E Product Manual Rev 1 02...

Page 14: ...rier Boards fitted with ETRX2 modules 1 x ETRX2 PA MCB with ETRX2 PA Module 1 x AA Battery Holders with leads 1 x USB cable 1 x ETRX2USB USB stick 1 x ETRX2HRHW PA Module with Hirose connector for ext...

Page 15: ...r improvements without prior notification All information is correct at time of issue Telegesis UK Ltd does not convey any license under its patent rights or assume any responsibility for the use of t...

Reviews: