R305 AT Commands
©2011 Telegesis (UK) Ltd
- 85 -
AT Command Manual (Rev 3.05)
4.6 Advanced Settings
S3E
– Multicast Table Entry 00
Description
The ID portion of Multicast Table Entry 00
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Note
Same effect as AT+MSET, but can be set at
boot-up by built-in functionality
Storage
Non-Volatile
Parameters
XXXX
If S3E
is not set to all 0‟s multicast table entry 1 to
endpoint 1 (the AT command layer‟s endpoint) is
set with the setting of this register is created
instantly and after a reset.
Factory Default
0000
SW release
R300
S3F
– Multicast Table Entry 01
Description
The ID portion of Multicast Table Entry 01
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Note
As for S3E
Storage
Non-Volatile
Parameters
XXXX
If
S3F is not set to all 0‟s multicast table entry 2 to
endpoint 1 (the AT command layer‟s endpoint) is
set with the setting of this register is created
instantly and after a reset.
Factory Default
0000
SW release
R300