R305 AT Commands
©2011 Telegesis (UK) Ltd
- 61 -
AT Command Manual (Rev 3.05)
S11
– Device Specific
Description
Defines the behaviour of the Device.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Note
On the ETRX2 series IRQ0,1,2,3 are
generated by logic transitions on inputs
I/O0,1,10,11 respectively, on the ETRX3
series they are generated by logic level
transitions on PA0, PA1, PB0 and PB6
respectively
Storage
Non-Volatile
Parameters
XXXX
Where XXXX represents a 16-bit hexadecimal
number.
Bit F (MSB):
Set: I/O3 (ETRX2) or PB7 (ETRX3) is
PWM as defined by S1B/S1D.
Unset: Standard I/O pin.
Bit E:
Set: Enable Boost Mode
Bit D:
Set: Present 1.2V A/D-Reference at I/O0
during measurement (ETRX2 only)
Bit C:
Set: I/O8 turns into A/D3, which can be read
from S21 (ETRX2 only)
Bit B:
Set: Pad 38 turns into A/D4, which can be
read from S22 (ETRX2 only)
Bit A:
Reserved
Bit 9:
Set: Enable wakeup on UART activity (1st
input character is discarded)
Bit 8:
Set: Enable 100ms debouncing for all IRQs
Bit 7:
Set: IRQ3 on rising edge
Bit 6:
Set: IRQ3 on falling edge
Bit 5:
Set: IRQ2 on rising edge
Bit 4:
Set: IRQ2 on falling edge
Bit 3:
Set: IRQ1 on rising edge
Bit 2:
Set: IRQ1 on falling edge
Bit 1:
Set: IRQ0 on rising edge
Bit 0:
Set: IRQ0 on falling edge
Factory Default
0005
SW release
R301