![Telefunken TECHCLIM9 Manual Download Page 33](http://html.mh-extra.com/html/telefunken/techclim9/techclim9_manual_1081235033.webp)
ENGLISH
LESS THAN 0.1% PER YEAR AS SET OUT IN THE TECHNICAL
SPECIFICATION OF THE MANUFACTURER. PLEASE FIND AS
BELOW THE QUANTITY OF FLUORINATED GREENHOUSE GASES
FOR WHICH THE EQUIPMENT IS DESIGNED AND THE GLOBAL
WARMING POTENTIAL OF THOSE GASES FOR EACH OF OUR AIR
CONDITIONNER.
BRAND
MODEL
GAS
TYPE
GWP
UNIT
GAS
WEIGHT
TEQ
CO2 BY
UNIT
Telefunken TECHCLIM9 R290
3.3
200 gr
0.00066
Telefunken TECHCLIM12 R290
3
210 gr
0.00063
•
R290 REFRIGERANT GAS COMPLIES WITH EUROPEAN
ENVIRONMENTAL DIRECTIVES. NEVER PERFORATE ANY PART
OF THE REFRIGERANT CIRCUIT ON THE APPLIANCE.
•
DO NOT LOAD MORE THAN 250G OF R290 PER APPLIANCE.
•
WARNING: BE AWARE THAT REFERIGERANT MAY NOT
CONTAIN AN ODOUR.
•
DO NOT PIERCE OR BURN.
•
APPLIANCE SHALL BE INSTALLED, OPERATED AND STORED IN A
ROOM WITH A FLOOR AREA LARGER THAN 12M2.
•
THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT
CONTINUOUSLY OPERATING IGNITION SOURCES (FOR
EXAMPLE: OPEN FLAMES, AN OPERATING GAS APPLIANCE OR
AN OPERATING ELECTRIC HEATER).
•
SERVICING SHALL ONLY PERFORMED BY A REFRIGERANT
SPECIALIST.
•
ANY PERSON WHO IS INVOLVED WITH WORKING ON OR
BREAKING INTO A REFRIGERANT CIRCUIT SHOULD HOLD A
CURRENT VALID CERTIFICATE FROM AN INDUSTRY-
ACCREDITED ASSESSMENT AUTHORITY. WHICH AUTHORIZES