6.
Turn the current coarse
and fine knobs fully
clockwise to the
maximum positions.
CURRENT
C.C.
COARSE
FINE
7.
Turn the current coarse
and fine knobs to the
centered position
CURRENT
C.C.
COARSE
FINE
8.
Adjust VR303 so that the multimeter displays
the following values.
T3PS11230
30.1A
T3PS12415
15.1A
T3PS16006
6.10A
9.
Adjust VR2 so that the current value of the
ammeter display matches the current shown in
the multimeter.
10.
Press the AMPS key to set the
current range to low.
11.
Adjust VR310 so that the multimeter displays
the following values. (half of the rating current)
T3PS11230
15.0A
T3PS12415
7.5A
T3PS16006
3.0A
12.
Adjust VR401 to set the OVP value.