background image

TELEDYNE FOXY JR

Clarity Control Module

ENG

Code/Rev.: M167/80C

Date: 8/24/2020

Phone: +420 251 013 400

DataApex Ltd.

Fax: +420 251 013 401

Petrzilkova 2583/13

[email protected]

158 00 Prague 5

www.dataapex.com

The Czech Republic

Summary of Contents for Foxy Jr

Page 1: ...FOXY JR Clarity Control Module ENG Code Rev M167 80C Date 8 24 2020 Phone 420251013400 DataApex Ltd Fax 420251013401 Petrzilkova 2583 13 clarity dataapex com 15800Prague 5 www dataapex com The Czech...

Page 2: ...emarks of DataApex Ltd Microsoft and WindowsTM are trademarks of Microsoft Corporation DataApex reserves the right to make changes to manuals without prior notice Updated manuals can be downloaded fro...

Page 3: ...ledyne Foxy Jr fraction collector communication 3 3 2 Clarity Configuration 4 4 Using the control module 6 4 1 Method Setup FC Fraction Table 7 4 2 Method Setup FC Vial Numbers 12 4 3 Hardware Configu...

Page 4: ...1 capitals indicates the name of the file and or directory ACTIVE capitalitalics marks the state of the station or its part The bold text is sometimes also used for important parts of the text and the...

Page 5: ...irect control of the instrument over serial line Fig 1 Teledyne Foxy Jr fraction collector Direct control means that the fraction collector can be completely controlled from the Clarity environment Th...

Page 6: ...for gas chromatographs or AS Control module p n A26 for autosamplers Free serial COM port in the PC Note Modern computers usually have only one if any serial COM port installed To use more devices req...

Page 7: ...e 3 Installation Procedure 3 1 Teledyne Foxy Jr fraction collector communication The Teledyne Foxy Jr is controlled by serial RS232 communication It uses a DB9F DB25F straight cable p n SK04 described...

Page 8: ...Teledyne Foxy Jr 3 Installation Procedure 3 2 Clarity Configuration Fig 3 How to add Teledyne Foxy Jr 4...

Page 9: ...ilable Control Modules dialog The DataApex UNI Setup dialog will appear Fig 4 DataApex UNI Setup Set the correct communication Port and click on the AutoDetect button to establish communication with t...

Page 10: ...g and setting up the new device one or more new tabs will appear in the Metho depending on the type of the instrument A new Teledyne Foxy Jrfraction collector section enabling the monitoring of the cu...

Page 11: ...is parameter together with the Fraction Volume parameter from the Fraction Table helps to prevent collection vial overflowing Flow rate units are taken from the Instrument Method Sending dialog Delay...

Page 12: ...will be terminated regardless on the current Signal Condition state See the description of Signal Condition below Fraction Volume Collected amount can be collected to one or more vials fractions The...

Page 13: ...ing image displays the course of the first derivative of the signal and demonstrates Slope Stop activation Read carefully the values of the slope in all End Fraction points and the course of the first...

Page 14: ...the fraction collection will not start stops when any of the stop signal conditions is fulfilled whatever occurs first detector signal decreases below Level Stop value or the first derivative of the d...

Page 15: ...ll be delayed the higher the Filter value is set mainly on detectors with low data rate Note Filter settings influence the value that should be set the Slope Start and Slope Stop columns To get the co...

Page 16: ...current vial number is incremented each time the Next signal is activated The vial number is stored in the Results Table Reset at Specifies the conditions of the current vial number setting to Start...

Page 17: ...ding dialog This functionality is not applicable even if checked when Collect All option is selected Change Vial when Collecting and Peak Top is Detected If enabled the vial is automatically swapped w...

Page 18: ...onfiguration The Hardware Configuration dialog invoked by using the FC Status button from the Method Setup LC Method Setup FC displays the configuration of the Teledyne Foxy Jr namely the communicatio...

Page 19: ...e button changes according to the state in which the fraction collector is while it is collecting the Waste button forces the fraction collector to stop collecting while it is in a waste cycle the Col...

Page 20: ...ect Properties to open the Graph Properties dialog and check the Show Events checkbox When the Fraction Delay is set there will be two colors present in the graph lighter and darker red The lighter re...

Page 21: ...the Clarity installation folder C CLARITY BIN by default Port Defines the communication port used possible values dependent on the type of communication of the device and or available ports in the PC...

Page 22: ...Teledyne Foxy Jr 4 Using the control module Rack Selection Allows the user to select the correct rack type installed on the Teledyne Foxy Jr fraction collector 18...

Page 23: ...by checking the Instrument Control checkbox on the Method tab of the Report Setup dialog Fig 12 Report Setup All of the parameters set in the Method Setup FC Fraction Table and Method Setup FC Vial Nu...

Page 24: ...ction should be edited or added COM1 echo on textmode on filename CommDrvCOM1_ D txt reset off Note Instead of COM1 type the communication port used to communicate with the Teledyne Foxy Jrfraction co...

Reviews: